The DOI matches its Crossref record.
Response rate accuracy in oncology trials: reasons for interobserver variability. Groupe Français d'Immunothérapie of the Fédération Nationale des Centres de Lutte Contre le Cancer.
Abstract
PURPOSE: We evaluated the impact of an evaluation committee (EC) on patients' overall response status in a large multicenter trial in oncology. We identified reasons for disagreements between investigators and the EC. MATERIALS AND METHODS: The Cancer Renal Cytokine (CRECY) study was a French multicenter trial that tested cytokine therapy in 489 patients with metastatic renal cell carcinoma. Objective response (OR) evaluation included medical imaging and was studied according to international guidelines. A blinded peer review of all responders and litigious cases was performed by an EC. RESULTS: Major disagreements occurred in 40% and minor disagreements in 10.5% of the reviewed files. The number of significant tumor responses was reduced by 23.2% after review by the EC. Reasons for disagreements included errors in tumor measurements, errors in selection of measurable targets, intercurrent diseases, and radiologic technical problems. These reasons for disagreements are analyzed and discussed. CONCLUSION: We conclude that all therapeutic trial results should be reviewed by peer analysis of all presumed responders by an EC. International guidelines for response evaluation should be updated by including more reliable methods of measurements and definition of minimal imaging procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803
Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials
(2015) · Neuro-Oncology · doi:10.1093/neuonc/nov095 · Cited by 663
Erasmus, J. J., Gladish, G. W., Broemeling, L., Sabloff, B. S., Truong, M. T., Herbst, R. S., & Munden, R. F. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.01.144 · Cited by 476
Modified Criteria for Radiographic Response Assessment in Glioblastoma Clinical Trials
Ellingson, B. M., Wen, P. Y., & Cloughesy, T. F. (2017) · Neurotherapeutics · doi:10.1007/s13311-016-0507-6 · Cited by 476
Perez, E. A., Lerzo, G., Pivot, X., Thomas, E., Vahdat, L., Bosserman, L., Viens, P., Cai, C., Mullaney, B., Peck, R., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.3849 · Cited by 393
Metadata
- Authors
- Thiesse, P., Ollivier, L., Di Stefano-Louineau, D., Négrier, S., Savary, J., Pignard, K., Lasset, C., & Escudier, B.
- Venue
- Journal of Clinical Oncology
- Published
- 1997-12
- Volume
- 15
- Issue
- 12
- Pages
- 3507-3514
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W1812456385
- Cited by
- 168
- References
- 0
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Response rate accuracy in oncology trials: reasons for interobserver variability. Groupe Français d'Immunothérapie of the Fédération Nationale des Centres de Lutte Contre le Cancer. https://app.cochat.ai/papers/10.1200/jco.1997.15.12.3507
- The paper
- Thiesse, P., Ollivier, L., Di Stefano-Louineau, D., Négrier, S., Savary, J., Pignard, K., Lasset, C., & Escudier, B. (1997). Response rate accuracy in oncology trials: reasons for interobserver variability. Groupe Français d'Immunothérapie of the Fédération Nationale des Centres de Lutte Contre le Cancer. Journal of Clinical Oncology. https://doi.org/10.1200/jco.1997.15.12.3507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.