Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,615

The DOI matches its OpenAlex record; 2 of the 2 references it cites were found in a registry or an index.

INT 0123 (Radiation Therapy Oncology Group 94-05) Phase III Trial of Combined-Modality Therapy for Esophageal Cancer: High-Dose Versus Standard-Dose Radiation Therapy

Bruce D. Minsky, Thomas F. Pajak, Robert J. Ginsberg, Thomas Michael Pisansky, James A. Martenson, Ritsuko U Komaki, Gordon S. Okawara, Seth A. Rosenthal, David Paul Kelsen·2002·Journal of Clinical Oncology

Abstract

PURPOSE: To compare the local/regional control, survival, and toxicity of combined-modality therapy using high-dose (64.8 Gy) versus standard-dose (50.4 Gy) radiation therapy for the treatment of patients with esophageal cancer. PATIENTS AND METHODS: A total of 236 patients with clinical stage T1 to T4, N0/1, M0 squamous cell carcinoma or adenocarcinoma selected for a nonsurgical approach, after stratification by weight loss, primary tumor size, and histology, were randomized to receive combined-modality therapy consisting of four monthly cycles of fluorouracil (5-FU) (1,000 mg/m(2)/24 hours for 4 days) and cisplatin (75 mg/m(2) bolus day 1) with concurrent 64.8 Gy versus the same chemotherapy schedule but with concurrent 50.4 Gy. The trial was stopped after an interim analysis. The median follow-up was 16.4 months for all patients and 29.5 months for patients still alive. RESULTS: For the 218 eligible patients, there was no significant difference in median survival (13.0 v 18.1 months), 2-year survival (31% v 40%), or local/regional failure and local/regional persistence of disease (56% v 52%) between the high-dose and standard-dose arms. Although 11 treatment-related deaths occurred in the high-dose arm compared with two in the standard-dose arm, seven of the 11 deaths occurred in patients who had received 50.4 Gy or less. CONCLUSION: The higher radiation dose did not increase survival or local/regional control. Although there was a higher treatment-related mortality rate in the patients assigned to the high-dose radiation arm, it did not seem to be related to the higher radiation dose. The standard radiation dose for patients treated with concurrent 5-FU and cisplatin chemotherapy is 50.4 Gy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1200/jco.20.5.1167

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 8

  1. 10.1056/NEJM199206113262403 · DOI · Paper page
  2. 10.1001/jama.281.17.1623 · DOI · Paper page
  3. 10.1016/S0360-3016(98)00463-5 · doi:10.1016/s0360-3016(98)00463-5
  4. 10.1200/JCO.1996.14.1.149 · doi:10.1200/jco.1996.14.1.149
  5. 10.1214/aos/1176350951 · DOI · Paper page
  6. 10.1016/0021-9681(74)90015-0 · DOI · Paper page
  7. 10.1002/(SICI)1097-0142(20000301)88:5<988::AID-CNCR7>3.0.CO;2-U · doi:10.1002/(sici)1097-0142(20000301)88:5<988::aid-cncr7>3.0.co;2-u
  8. 10.1081/CNV-100000068 · doi:10.1081/cnv-100000068

Cited by

See all 1,615

Metadata

Authors
Minsky, B. D., Pajak, T. F., Ginsberg, R. J., Pisansky, T. M., Martenson, J. A., Komaki, R. U., Okawara, G. S., Rosenthal, S. A., & Kelsen, D. P.
Venue
Journal of Clinical Oncology
Published
2002-03-01
Volume
20
Issue
5
Pages
1167-1174
ISSN
  • 0732-183X (ISSN-L)
  • 1527-7755
OpenAlex
W2117223681
Cited by
1,615
References
2
FWCI
24.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: INT 0123 (Radiation Therapy Oncology Group 94-05) Phase III Trial of Combined-Modality Therapy for Esophageal Cancer: High-Dose Versus Standard-Dose Radiation Therapy. https://app.cochat.ai/papers/10.1200/jco.20.5.1167
The paper
Minsky, B. D., Pajak, T. F., Ginsberg, R. J., Pisansky, T. M., Martenson, J. A., Komaki, R. U., Okawara, G. S., Rosenthal, S. A., & Kelsen, D. P. (2002). INT 0123 (Radiation Therapy Oncology Group 94-05) Phase III Trial of Combined-Modality Therapy for Esophageal Cancer: High-Dose Versus Standard-Dose Radiation Therapy. Journal of Clinical Oncology. https://doi.org/10.1200/jco.20.5.1167

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.