Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 270

The DOI matches its Crossref record.

Comparison of Diameter and Perimeter Methods for Tumor Volume Calculation

Sorensen, A. Gregory, Patel, Shveta, Harmath, Carla, Bridges, Sarah, Synnott, Jennifer, Sievers, Amy, Yoon, Young-Ho, Lee, E. John, Yang, Michael C., Lewis, Robert F., Harris, Gordon J., Lev, Michael, Schaefer, Pamela W., Buchbinder, Bradley R., Barest, Glenn, Yamada, Kei, Ponzo, John, Kwon, H. Young, Gemmete, Joseph, Farkas, Jeff, Tievsky, Andrew L., Ziegler, Richard B., Salhus, Megan R.C., Weisskoff, Robert·2001·Journal of Clinical Oncology

Abstract

PURPOSE: Lesion volume is often used as an end point in clinical trials of oncology therapy. We sought to compare the common method of using orthogonal diameters to estimate lesion volume (the diameter method) with a computer-assisted planimetric technique (the perimeter method). METHODS: Radiologists reviewed 825 magnetic resonance imaging studies from 219 patients with glioblastoma multiforme. Each study had lesion volume independently estimated via the diameter and perimeter methods. Cystic areas were subtracted out or excluded from the outlined lesion. Inter- and intrareader variability was measured by using multiple readings on 48 cases. Where serial studies were available in noncystic cases, a mock response analysis was used. RESULTS: The perimeter method had a reduced interreader and intrareader variability compared with the diameter method (using SD of differences): intrareader, 1.76 mL v 7.38 mL (P < .001); interreader, 2.51 mL v 9.07 mL (P < .001) for perimeter and diameter results, respectively. Of the 121 noncystic cases, 23 had serial data. In six (26.1%) of those 23, a classification difference occurred when the perimeter method was used versus the diameter method. CONCLUSION: Variability of measurements was reduced with the computer-assisted perimeter method compared with the diameter method, which suggests that changes in volume can be detected more accurately with the perimeter method. The differences between these techniques seem large enough to have an impact on grading the response to therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1200/jco.2001.19.2.551

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 10

  1. 10.1016/S0730-725X(97)00302-0 · DOI
  2. 10.1097/00004728-198907000-00006 · DOI · Paper page
  3. 10.1001/archneur.1990.00530010035015 · DOI · Paper page
  4. 10.1016/0925-4927(92)90012-S · DOI
  5. 10.1016/0920-9964(91)90037-R · DOI
  6. 10.1002/ana.410250110 · DOI
  7. 10.1109/42.20356 · DOI · Paper page
  8. 10.1016/S0022-5223(98)70274-0 · doi:10.1016/s0022-5223(98)70274-0
  9. 10.1097/00004728-198104000-00015 · DOI
  10. 10.1016/0925-4927(91)90029-P · doi:10.1016/0925-4927(91)90029-p

Cited by

See all 270

Metadata

Authors
Sorensen, A. G., Patel, S., Harmath, C., Bridges, S., Synnott, J., Sievers, A., Yoon, Y.-H., Lee, E. J., Yang, M. C., Lewis, R. F., Harris, G. J., Lev, M., Schaefer, P. W., Buchbinder, B. R., Barest, G., Yamada, K., Ponzo, J., Kwon, H. Y., Gemmete, J., Farkas, J., Tievsky, A. L., Ziegler, R. B., Salhus, M. R. C., & Weisskoff, R.
Venue
Journal of Clinical Oncology
Published
2001-01-15
Volume
19
Issue
2
Pages
551-557
ISSN
  • 0732-183X (ISSN-L)
  • 1527-7755
OpenAlex
W1947046122
Cited by
270
References
0
FWCI
2.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Diameter and Perimeter Methods for Tumor Volume Calculation. https://app.cochat.ai/papers/10.1200/jco.2001.19.2.551
The paper
Sorensen, A. G., Patel, S., Harmath, C., Bridges, S., Synnott, J., Sievers, A., Yoon, Y.-H., Lee, E. J., Yang, M. C., Lewis, R. F., Harris, G. J., Lev, M., Schaefer, P. W., Buchbinder, B. R., Barest, G., Yamada, K., Ponzo, J., Kwon, H. Y., Gemmete, J., . . . Weisskoff, R. (2001). Comparison of Diameter and Perimeter Methods for Tumor Volume Calculation. Journal of Clinical Oncology. https://doi.org/10.1200/jco.2001.19.2.551

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.