CoChat

Phase I Dose-Escalation Study of Stereotactic Body Radiation Therapy for Low- and Intermediate-Risk Prostate Cancer

Open access
Boike, Thomas P., Lotan, Yair, Cho, L. Chinsoo, Brindle, Jeffrey, DeRose, Paul, Xie, Xian-Jin, Yan, Jingsheng, Foster, Ryan, Pistenmaa, David, Perkins, Alida, Cooley, Susan, Timmerman, Robert · 2011 · Journal of Clinical Oncology
Cited by 246

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Purpose: To evaluate the tolerability of escalating doses of stereotactic body radiation therapy in the treatment of localized prostate cancer. Patients and Methods: Eligible patients included those with Gleason score 2 to 6 with prostate-specific antigen (PSA) ≤ 20, Gleason score 7 with PSA ≤ 15, ≤ T2b, prostate size ≤ 60 cm 3, and American Urological Association (AUA) score ≤ 15. Pretreatment preparation required an enema and placement of a rectal balloon. Dose-limiting toxicity (DLT) was defined as grade 3 or worse GI/genitourinary (GU) toxicity by Common Terminology Criteria of Adverse Events (version 3). Patients completed quality-of-life questionnaires at defined intervals. Results: Groups of 15 patients received 45 Gy, 47.5 Gy, and 50 Gy in five fractions (45 total patients). The median follow-up is 30 months (range, 3 to 36 months), 18 months (range, 0 to 30 months), and 12 months (range, 3 to 18 months) for the 45 Gy, 47.5 Gy, and 50 Gy groups, respectively. For all patients, GI grade ≥ 2 and grade ≥ 3 toxicity occurred in 18% and 2%, respectively, and GU grade ≥ 2 and grade ≥ 3 toxicity occurred in 31% and 4%, respectively. Mean AUA scores increased significantly from baseline in the 47.5-Gy dose level (P = .002) as compared with the other dose levels, where mean values returned to baseline. Rectal quality-of-life scores (Expanded Prostate Cancer Index Composite) fell from baseline up to 12 months but trended back at 18 months. In all patients, PSA control is 100% by the nadir + 2 ng/mL failure definition. Conclusion: Dose escalation to 50 Gy has been completed without DLT. A multicenter phase II trial is underway treating patients to 50 Gy in five fractions to further evaluate this experimental therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1200/jco.2010.31.4377

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

Metadata

Authors
Boike, T. P., Lotan, Y., Cho, L. C., Brindle, J., DeRose, P., Xie, X.-J., Yan, J., Foster, R., Pistenmaa, D., Perkins, A., Cooley, S., & Timmerman, R.
Venue
Journal of Clinical Oncology
Published
2011-05-20
Volume
29
Issue
15
Pages
2020-2026
ISSN
  • 0732-183X (ISSN-L)
  • 1527-7755
OpenAlex
W2127707619
Cited by
246
References
18
FWCI
21.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.