Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record.

Variability of Lung Tumor Measurements on Repeat Computed Tomography Scans Taken Within 15 Minutes

Open access
Oxnard, Geoffrey R., Zhao, Binsheng, Sima, Camelia S., Ginsberg, Michelle S., James, Leonard P., Lefkowitz, Robert A., Guo, Pingzhen, Kris, Mark G., Schwartz, Lawrence H., Riely, Gregory J.·2011·Journal of Clinical Oncology

Abstract

Purpose: We use changes in tumor measurements to assess response and progression, both in routine care and as the primary objective of clinical trials. However, the variability of computed tomography (CT) –based tumor measurement has not been comprehensively evaluated. In this study, we assess the variability of lung tumor measurement using repeat CT scans performed within 15 minutes of each other and discuss the implications of this variability in a clinical context. Patients and Methods: Patients with non–small-cell lung cancer and a target lung lesion ≥ 1 cm consented to undergo two CT scans within a period of minutes. Three experienced radiologists measured the diameter of the target lesion on the two scans in a side-by-side fashion, and differences were compared. Results: Fifty-seven percent of changes exceeded 1 mm in magnitude, and 33% of changes exceeded 2 mm. Median increase and decrease in tumor measurements were +4.3% and −4.2%, respectively, and ranged from 23% shrinkage to 31% growth. Measurement changes were within ± 10% for 84% of measurements, whereas 3% met criteria for progression according to Response Evaluation Criteria in Solid Tumors (RECIST; ≥ 20% increase). Smaller lesions had greater variability of percent measurement change (P = .005). Conclusion: Apparent changes in tumor diameter exceeding 1 to 2 mm are common on immediate reimaging. Increases and decreases less than 10% can be a result of the inherent variability of reimaging. Caution should be exercised in interpreting the significance of small changes in lesion size in the care of individual patients and in the interpretation of clinical trial results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1200/jco.2010.33.7071

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Oxnard, G. R., Zhao, B., Sima, C. S., Ginsberg, M. S., James, L. P., Lefkowitz, R. A., Guo, P., Kris, M. G., Schwartz, L. H., & Riely, G. J.
Venue
Journal of Clinical Oncology
Published
2011-08-10
Volume
29
Issue
23
Pages
3114-3119
ISSN
  • 0732-183X (ISSN-L)
  • 1527-7755
OpenAlex
W2122538591
Cited by
161
References
0
FWCI
12.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability of Lung Tumor Measurements on Repeat Computed Tomography Scans Taken Within 15 Minutes. https://app.cochat.ai/papers/10.1200/jco.2010.33.7071
The paper
Oxnard, G. R., Zhao, B., Sima, C. S., Ginsberg, M. S., James, L. P., Lefkowitz, R. A., Guo, P., Kris, M. G., Schwartz, L. H., & Riely, G. J. (2011). Variability of Lung Tumor Measurements on Repeat Computed Tomography Scans Taken Within 15 Minutes. Journal of Clinical Oncology. https://doi.org/10.1200/jco.2010.33.7071

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.