CoChat

Development and analytical performance of a molecular diagnostic for anti-PD1 response on the nCounter Dx Analysis System.

Wallden, Brett, Pekker, Irena, Popa, Simina, Dowidar, Naeem, Sullivan, Amy, Hood, Tressa, Danaher, Patrick, Mashadi-Hossein, Afshin, Lunceford, Jared K., Marton, Matthew John, Chang, Ken C. N., Ferree, Sean, Storhoff, James Justin · 2016 · Journal of Clinical Oncology
Cited by 18

The DOI matches its Crossref record.

Abstract

3034 Background: Pembrolizumab is a humanized anti-PD1 antibody that is FDA approved for use in patients with advanced melanoma and in selected patients with metastatic non-small-cell lung cancer. It has also shown clinical activity in a number of other tumor types in clinical trials, but there is need for a precise and accurate test that can identify patients most likely to benefit from therapy. Several immune-related gene expression (Gx) signatures in formalin fixed, paraffin embedded (FFPE) tissue were previously reported to enrich for responders to pembrolizumab across different tumor types. We have developed a clinical trial assay, referred to here as the anti-PD1 Gx test, based on genes repeatedly found to be associated with improved response to pembrolizumab in a number of cancers. Here we describe the development and analytical performance of the anti-PD1 Gx test in multiple tumor types. Methods: The anti-PD1 Predictor Score (PS) algorithm was trained using RNA from FFPE specimens from all cancer types in the KEYNOTE-012 trial and several cancer types in the KEYNOTE-028 trial (anal canal, biliary tract, colorectal, esophageal, and ovarian) to determine the final genes and weightings. Analytical precision from RNA, reproducibility from multiple tissue blocks, impact of intra-tumor heterogeneity, and sensitivity to RNA input amount were measured across operators using samples from multiple tumor types. The robustness of the assay was evaluated with the inclusion of adjacent non-tumor tissue. Results: The total standard deviation in anti-PD1 PS was < 5% of the score range with random error being the major source of variance. The assay was robust across the specified RNA input range and against the inclusion of non-tumor tissue. The major source of variability in Gx across multiple tumor types was associated with the tumors’ immune Gx signature rather than intra-tumor variability or even tumor type. Conclusions: The NanoString anti-PD1 Gx test is a robust assay, which profiles immune related Gx across multiple cancer types. The assay is well suited to clinical applications and its ability to identify responders to anti-PD1 therapy is being investigated in multiple indications in several studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1200/jco.2016.34.15_suppl.3034

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 18

Metadata

Authors
Wallden, B., Pekker, I., Popa, S., Dowidar, N., Sullivan, A., Hood, T., Danaher, P., Mashadi-Hossein, A., Lunceford, J. K., Marton, M. J., Chang, K. C. N., Ferree, S., & Storhoff, J. J.
Venue
Journal of Clinical Oncology
Published
2016-05-20
Volume
34
Issue
15_suppl
Pages
3034-3034
ISSN
  • 0732-183X (ISSN-L)
  • 1527-7755
OpenAlex
W2747213610
Cited by
18
References
0
Type
conference abstract
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and analytical performance of a molecular diagnostic for anti-PD1 response on the nCounter Dx Analysis System. https://app.cochat.ai/papers/10.1200/jco.2016.34.15_suppl.3034
The paper
Wallden, B., Pekker, I., Popa, S., Dowidar, N., Sullivan, A., Hood, T., Danaher, P., Mashadi-Hossein, A., Lunceford, J. K., Marton, M. J., Chang, K. C. N., Ferree, S., & Storhoff, J. J. (2016). Development and analytical performance of a molecular diagnostic for anti-PD1 response on the nCounter Dx Analysis System. Journal of Clinical Oncology. https://doi.org/10.1200/jco.2016.34.15_suppl.3034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.