Electrical Impedance Tomography
The DOI matches its OpenAlex record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This short chapter describes the physics of an imaging method known as electrical impedance tomography (EIT), which involves reconstructing an image where contrast is due to variations in the ability of the tissue to allow the passage of (usually alternating) electrical current. The physiological origins of such variations are reviewed, and it is discussed how these might reveal information of diagnostic value. The underlying mathematics of EIT image reconstruction is presented, including an indication of how assumptions inherent in various practical approaches can limit their performance in practice. Alternative EIT data acquisition protocols are briefly examined, and the instrumentation developed for medical applications of EIT is described. The chapter concludes with a brief summary of current and likely future diagnostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Barber, D. C., & Brown, B. H. (1984) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/17/9/002 · Cited by 726
Zhao, Z., Möller, K., Steinmann, D., Frerichs, I., & Guttmann, J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1589-y · Cited by 321
Zhao, Z., Steinmann, D., Frerichs, I., Guttmann, J., & Möller, K. (2010) · Critical Care · doi:10.1186/cc8860 · Cited by 209
Cardiac and respiratory related electrical impedance changes in the human thorax
Brown, B. H., Barber, D. C., Morice, A. H., & Leathard, A. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.310088 · Cited by 125
Dielectric properties of lung tissue as a function of air content
Nopp, P., Rapp, E., Pfutzner, H., Nakesch, H., & Rusham, C. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/6/005 · Cited by 107
Zhao, Z., Steinmann, D., Müller-Zivkovic, D., Martin, J., Frerichs, I., Guttmann, J., & Möller, K. (2010) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2010-0252 · Cited by 34
Cited by
Electrical impedance tomography and Calderón's problem
Uhlmann, G. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123011 · Cited by 416
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Tomo: Wearable, Low-Cost Electrical Impedance Tomography for Hand Gesture Recognition
Zhang, Y., & Harrison, C. (2015) · Proceedings of the 28th Annual ACM Symposium on User Interface Software & Technology · doi:10.1145/2807442.2807480 · Cited by 283
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
Metadata
- Authors
- Holder, D. S., & Aristovich, K. Y.
- Venue
- CRC Press eBooks
- Publisher
- CRC Press
- Published
- 2004-12-31
- Pages
- 381-391
- OpenAlex
- W2053510218
- Cited by
- 815
- References
- 7
- FWCI
- 103.53
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.