Metastability and the Casimir effect in micromechanical systems
Open accessThe DOI matches its Crossref record.
Abstract
Electrostatic and Casimir interactions limit the range of positional stability of electrostatically actuated or capacitively coupled mechanical devices. We investigate this range experimentally for a generic system consisting of a doubly clamped Au suspended beam, capacitively coupled to an adjacent stationary electrode. The mechanical properties of the beam, both in the linear and nonlinear regimes, are monitored as the attractive forces are increased to the point of instability. There “pull-in” occurs, resulting in permanent adhesion between the electrodes. We investigate, experimentally and theoretically, the position-dependent lifetimes of the free state (existing prior to pull-in). We find that the data cannot be accounted for by simple theory; the discrepancy may be reflective of internal structural instabilities within the metal electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in the Casimir Effect
Bordag, M., Klimchitskaya, G. L., Mohideen, U., & Mostepanenko, V. M. (2009) · doi:10.1093/acprof:oso/9780199238743.001.0001 · Cited by 1,284
The Casimir force: background, experiments, and applications
Lamoreaux, S. K. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/1/r04 · Cited by 592
Nonlinear Micromechanical Casimir Oscillator
Chan, H. B., Aksyuk, V. A., Kleiman, R. N., Bishop, D. J., & Capasso, F. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.211801 · Cited by 484
The Casimir effect in microstructured geometries
Rodriguez, A. W., Capasso, F., & Johnson, S. G. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.39 · Cited by 475
Nonlinear Dynamics and Its Applications in Micro- and Nanoresonators
Rhoads, J. F., Shaw, S. W., & Turner, K. L. (2010) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.4001333 · Cited by 302
Review of modeling electrostatically actuated microelectromechanical systems
Batra, R. C., Porfiri, M., & Spinello, D. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/6/r01 · Cited by 287
Casimir Forces and Quantum Electrodynamical Torques: Physics and Nanomechanics
Capasso, F., Munday, J. N., Iannuzzi, D., & Chan, H. B. (2007) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.893082 · Cited by 251
“tromechanical systems (MEMS and NEMS) [24], [54], [55].”
Nonlinear damping in a micromechanical oscillator
Zaitsev, S., Shtempluck, O., Buks, E., & Gottlieb, O. (2012) · Nonlinear Dynamics · doi:10.1007/s11071-011-0031-5 · Cited by 209
“With a relatively modest driving force, the system is driven into the region of nonlinear oscillations [16, 71].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Buks, E., & Roukes, M. L.
- Venue
- Europhysics Letters (EPL)
- Publisher
- IOP Publishing
- Published
- 2001-04
- Volume
- 54
- Issue
- 2
- Pages
- 220-226
- ISSN
- 0295-5075 (ISSN-L)
- 1286-4854
- OpenAlex
- W2136494074
- Cited by
- 188
- References
- 0
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.