A Nonradioactive Uptake Assay for Rapid Analysis of Thyroid Hormone Transporter Function

Jayarama-Naidu, Roopa, Johannes, Jörg, Meyer, Franziska, Wirth, Eva Katrin, Schomburg, Lutz, Köhrle, Josef, Renko, Kostja · 2015 · Endocrinology
Cited by 36

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Thyroid hormones (TH) are actively taken up into target cells via TH-transmembrane transporters (THTT). Their activity and expression patterns define a layer of endocrine regulation that is poorly understood. Therefore, THTT are potential targets for interfering agents (endocrine disruptors) as well as for pharmacological interventions. Inactivating mutations have been identified as the underlying cause of heritable diseases (monocarboxylate transporter 8-associated Allan-Herndon-Dudley syndrome) and might also define a class of subclinical TH insensitivity. As a basic tool to solve questions regarding THTT substrate specificity, activation or inactivation by compounds and functional changes from mutations, uptake assays with radiolabeled tracers are standard. Due to the need for radioactive isotopes, this technique is limited to screening of labelled substrates and disadvantageous regarding handling, setup, and regulatory issues. To overcome these hurdles, we developed an uptake assay protocol using nonradioactive ligands. In brief, uptake of nonradioactive iodine-containing substrate molecules was monitored via Sandell-Kolthoff reaction. The novel assay was designed to the common microtiter plate layout. As a prove-of-principle, we measured TH uptake by monocarboxylate transporter 8-transfected MDCK1 cells. Titrations with bromosulphthalein as an example for inhibitor screening setups and a side-by-side comparison with the radioactive method prove this assay to be reliable, sensitive, and convenient. Furthermore, the method was applicable on primary murine astrocytes, which enables high-throughput screening studies on in vitro model systems with physiological transporter regulation. Due to its design, it is applicable for high-throughput screening of modulatory compounds, but it is also a safe, inexpensive and an easily accessible method for functional testing of THTT in basic science.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/en.2015-1016

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 36

Metadata

Authors
Jayarama-Naidu, R., Johannes, J., Meyer, F., Wirth, E. K., Schomburg, L., Köhrle, J., & Renko, K.
Venue
Endocrinology
Published
2015-04-24
Volume
156
Issue
7
Pages
2739-2745
ISSN
  • 0013-7227 (ISSN-L)
  • 1945-7170
OpenAlex
W2063062076
Cited by
36
References
2
FWCI
1.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.