In Vivo Biological Validation and Biophysical Modeling of the Sensitivity and Positive Accuracy of Endocrine Peak Detection. I. The LH Pulse Signal*
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The false positive (type I) and false negative (type II) errors inherent in computerized peak detection algorithms can have a major impact on the valid interpretation of physiological experiments. To objectively define the nature and extent of statistical errors associated with the identification of episodic gonadotropin (LH) peaks, we have employed two complementary approaches. First, using a general biophysical model for simulating episodic LH secretion, we have estimated optimal pulse analysis parameters that yield maximal sensitivity (probability of finding any given peak) and positive accuracy (probability that any identified peak is a true pulse) in synthetic LH series approximating those observed spontaneously in vivo. Secondly, we have estimated optimal peak detection parameters in an in vivo primate animal model, in which electrophysiological correlates of spontaneous LH pulses were documented independently by continuous electrophysiological monitoring of medial basal hypothalamus multiunit activity. These combined approaches indicate that LH time series can be analyzed for episodic LH pulsatility by an appropriately constrained, objective computerized algorithm with minimal false negative and false positive errors, i.e. with resultant high sensitivity and positive accuracy. Moreover, optimal pulse analysis parameters exhibited similar sensitivity and positive accuracy rates in both the biophysical simulations and the animal model. Thus, we suggest that the combined use of an algebraically explicit biophysical simulation model and an in vivo animal paradigm may serve to clarify the nature and extent of false negative and false positive errors in the detection of other hormone peaks as well as the gonadotropin LH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wilson, R. C., Kesner, J. S., Kaufman, J.-M., Uemura, T., Akema, T., & Knobil, E. (1984) · Neuroendocrinology · doi:10.1159/000123988 · Cited by 265
Cited by
EVANS, W. S., SOLLENBERGER, M. J., BOOTH, R. A., ROGOL, A. D., URBAN, R. J., CARLSEN, E. C., JOHNSON, M. L., & VELDHUIS, J. D. (1992) · Endocrine Reviews · doi:10.1210/edrv-13-1-81 · Cited by 285
Self-citation[26] Deconvolution analysis of hormone data
.Veldhuis, J. D., & Johnson, M. L. (1992) · Methods in Enzymology · doi:10.1016/0076-6879(92)10028-c · Cited by 263
Self-citationMotivations and Methods for Analyzing Pulsatile Hormone Secretion
Veldhuis, J. D., Keenan, D. M., & Pincus, S. M. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0005 · Cited by 223
Self-citationLoucks, A. B. (1994) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.78.4.910 · Cited by 174
LIU, C. H., LAUGHLIN, G. A., FISCHER, U. G., & YEN, S. S. C. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-71-4-900 · Cited by 155
Metadata
- Authors
- URBAN, R. J., JOHNSON, M. L., & VELDHUIS, J. D.
- Venue
- Endocrinology
- Publisher
- The Endocrine Society
- Published
- 1989-05
- Volume
- 124
- Issue
- 5
- Pages
- 2541-2547
- ISSN
- 0013-7227 (ISSN-L)
- 1945-7170
- OpenAlex
- W2159101625
- Cited by
- 90
- References
- 1
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Biological Validation and Biophysical Modeling of the Sensitivity and Positive Accuracy of Endocrine Peak Detection. I. The LH Pulse Signal*. https://app.cochat.ai/papers/10.1210/endo-124-5-2541
- The paper
- URBAN, R. J., JOHNSON, M. L., & VELDHUIS, J. D. (1989). In Vivo Biological Validation and Biophysical Modeling of the Sensitivity and Positive Accuracy of Endocrine Peak Detection. I. The LH Pulse Signal*. Endocrinology. https://doi.org/10.1210/endo-124-5-2541
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.