Combined Stimulation of Adrenocorticotropin and Compound-S by Single Dose Metyrapone Test as an Outpatient Procedure to Assess Hypothalamic-Pituitary-Adrenal Function
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The metyrapone test is used to test the hypothalamic-pituitary-adrenocortical axis. The present study aims to assess the diagnostic accuracy of combined stimulation of ACTH and compound-S (CMP-S). In addition, we analyzed the safety and practicability of this test as an outpatient procedure. A total of 327 metyrapone tests were analyzed retrospectively in 185 patients (mean age, 50.3 +/- 15.2 yr). One hundred thirteen patients had one test, and 72 patients had between 2 and 6 tests over 1-3 yr. Most patients suffered from pituitary adenomas (60 macroadenomas, 63 microadenomas) or other pituitary lesions (n = 29). Metyrapone (2 g) was given at 2400 h as an outpatient procedure. Blood samples for analysis of ACTH, CMP-S, and cortisol were taken at 0730 h. Stimulation of adrenal CMP-S and cortisol by pituitary ACTH demonstrated a dose-response curve with the shape of half a geometric parabola. CMP-S reached a plateau when ACTH rose above 175 ng/liter [r = 0.661, P < 0.0001 for ACTH <175 ng/liter; r = 0.083, P = not significant (NS) for ACTH >175 ng/liter], cortisol flattened at ACTH levels above 230 ng/liter (r = 0.633; P < 0.0001 for ACTH < 230 ng/liter; P = NS for ACTH >230 ng/liter). Alternatively, the sum of CMP-S plus cortisol also flattened when ACTH rose above 230 ng/liter (r = 0.696; P < 0.0001 for ACTH <230; P = NS for ACTH > 230 ng/liter). Receiver operating curve analysis defining a cut-off for ACTH at 150 ng/liter demonstrated a sensitivity of 47% and 67% at a cut-off level for CMP-S at 200 or 260 nmol/liter, respectively. The respective specificity was 82% and 68% for CMP-S. This compared with a sensitivity of 71% and specificity of 69% if the sum of CMP-S plus cortisol of 450 nmol/liter were used as cut-off. The response curve between CMP-S and ACTH implies a maximally stimulated adrenal cortex at circulating ACTH levels above 175 ng/liter. Single measurement of CMP-S using the cut-off at 200 nmol/liter, as suggested in the literature, yields a poor sensitivity of only 47% compared with ACTH. Despite the relatively high cross-reactivity of CMP-S in the cortisol assay, the sum of CMP-S and cortisol levels with a cut-off value of 450 nmol/liter yields a better diagnostic accuracy compared with CMP-S alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Natural History of Pituitary-Adrenal Recovery Following Long-Term Suppression with Corticosteroids1
GRABER, A. L., NEY, R. L., NICHOLSON, W. E., ISLAND, D. P., & LIDDLE, G. W. (1965) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-25-1-11 · Cited by 375
Comparison of low and high dose corticotropin stimulation tests in patients with pituitary disease
Mayenknecht, J., Diederich, S., Bähr, V., Plöckinger, U., & Oelkers, W. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.5.4831 · Cited by 142
Soule, S., Van Zyl Smit, C., Parolis, G., Attenborough, S., Peter, D., Kinvig, S., Kinvig, T., & Coetzer, E. (2000) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2000.01057.x · Cited by 59
Hartzband, P. I., Van Herle, A. J., Sorger, L., & Cope, D. (1988) · Journal of Endocrinological Investigation · doi:10.1007/bf03350221 · Cited by 46
Miró, J., Amado, J. A., Pesquera, C., López-Cordovilla, J. J., & Berciano, J. (2009) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1990.tb01013.x · Cited by 13
Cited by
Cortisol Response in Relation to the Severity of Stress and Illness
Widmer, I. E., Puder, J. J., König, C., Pargger, H., Zerkowski, H. R., Girard, J., & Müller, B. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0354 · Cited by 225
“I OUTPATIENTS, THE integrity of the hypothalamicpituitary-adrenal (HPA) axis can be assessed by stimulation with synthetic ACTH1–24 (Synacthen), among others (1).”
BackgroundSelf-citationHahner, S., Ross, R. J., Arlt, W., Bancos, I., Burger-Stritt, S., Torpy, D. J., Husebye, E. S., & Quinkler, M. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00252-7 · Cited by 223
Krasowski, M. D., Drees, D., Morris, C. S., Maakestad, J., Blau, J. L., & Ekins, S. (2014) · BMC Clinical Pathology · doi:10.1186/1472-6890-14-33 · Cited by 212
Raff, H., Sharma, S. T., & Nieman, L. K. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130035 · Cited by 141
“Traditionally, one could evaluate the loss of cortisol negative feedback by measuring the magnitude of the increase in plasma ACTH and/or 11-deoxycortisol (the substrate for 11-beta-hydroxylase) (24, 72).”
Radiation-induced hypopituitarism
Fernandez, A., Brada, M., Zabuliene, L., Karavitaki, N., & Wass, J. A. H. (2009) · Endocrine-Related Cancer · doi:10.1677/erc-08-0231 · Cited by 84
Metadata
- Authors
- Berneis, K., Staub, J. J., Gessler, A., Meier, C., Girard, J., & Müller, B.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2002-12
- Volume
- 87
- Issue
- 12
- Pages
- 5470-5475
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2165072455
- Cited by
- 65
- References
- 5
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Stimulation of Adrenocorticotropin and Compound-S by Single Dose Metyrapone Test as an Outpatient Procedure to Assess Hypothalamic-Pituitary-Adrenal Function. https://app.cochat.ai/papers/10.1210/jc.2001-011959
- The paper
- Berneis, K., Staub, J. J., Gessler, A., Meier, C., Girard, J., & Müller, B. (2002). Combined Stimulation of Adrenocorticotropin and Compound-S by Single Dose Metyrapone Test as an Outpatient Procedure to Assess Hypothalamic-Pituitary-Adrenal Function. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2001-011959
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.