CoChat

Accuracy of Bilateral Inferior Petrosal or Cavernous Sinuses Sampling in Predicting the Lateralization of Cushing’s Disease Pituitary Microadenoma: Influence of Catheter Position and Anatomy of Venous Drainage

Lefournier, Virginie, Martinie, Monique, Vasdev, Ashok, Bessou, Pierre, Passagia, Jean-Guy, Labat-Moleur, Françoise, Sturm, Nathalie, Bosson, Jean-Luc, Bachelot, Ivan, Chabre, Olivier · 2003 · The Journal of Clinical Endocrinology & Metabolism
Cited by 145

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Bilateral inferior petrosal sinus sampling (BIPSS) is the most reliable procedure for distinguishing Cushing's disease from ectopic ACTH secretion. However, it is less reliable at predicting the lateralization of the pituitary corticotroph microadenoma. We sought to determine whether this could be improved by taking into account the pattern of venous drainage and the precise location of the catheters. We retrospectively studied data from 86 patients who underwent BIPSS. Cushing's disease was predicted in 74 patients, of whom 69 underwent transsphenoidal surgery. Surgical cure was obtained in 65 patients, with identification of a corticotroph microadenoma in 58 cases. In 49 patients the location of the microadenoma predicted by the intersinus ACTH gradient could be compared with the pathologist's data. BIPSS accurately predicted the lateralization of the microadenoma in only 57% of these patients. Prediction was improved to 71% when both venograms and catheters were symmetric (35 patients). In this subgroup accuracy was 86% in patients with both catheters in the inferior petrosal sinuses compared with 50% in patients with both catheters in the cavernous sinuses (CS). Two transient sixth nerve palsies occurred during CS catheterization. Our data suggest that BIPSS results are much improved when venous drainage is symmetric. Catheterization of CS did not improve the results and was less safe.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2002-020374

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 145

Metadata

Authors
Lefournier, V., Martinie, M., Vasdev, A., Bessou, P., Passagia, J.-G., Labat-Moleur, F., Sturm, N., Bosson, J.-L., Bachelot, I., & Chabre, O.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2003-01
Volume
88
Issue
1
Pages
196-203
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2040401023
Cited by
145
References
2
FWCI
3.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Bilateral Inferior Petrosal or Cavernous Sinuses Sampling in Predicting the Lateralization of Cushing’s Disease Pituitary Microadenoma: Influence of Catheter Position and Anatomy of Venous Drainage. https://app.cochat.ai/papers/10.1210/jc.2002-020374
The paper
Lefournier, V., Martinie, M., Vasdev, A., Bessou, P., Passagia, J.-G., Labat-Moleur, F., Sturm, N., Bosson, J.-L., Bachelot, I., & Chabre, O. (2003). Accuracy of Bilateral Inferior Petrosal or Cavernous Sinuses Sampling in Predicting the Lateralization of Cushing’s Disease Pituitary Microadenoma: Influence of Catheter Position and Anatomy of Venous Drainage. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2002-020374

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.