Cundy, Tim, Ames, Ruth, Horne, Anne, Clearwater, Judy, Roberts, Helen, Gamble, Greg, Reid, Ian R. · 2003 · The Journal of Clinical Endocrinology & Metabolism
Cited by 83

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Long-term use of the injectable contraceptive depot medroxyprogesterone acetate (DMPA, Depo-Provera) is associated with a reduction in bone mineral density (BMD), particularly in the lumbar spine. The cause of DMPA-associated bone loss is not known, but the relative estrogen deficiency induced by DMPA use could be responsible. We have undertaken a randomized, double-blind controlled trial of oral estrogen replacement therapy in 38 premenopausal women (mean age 37) with a minimum 2 yr DMPA use who had a below average baseline lumbar spine BMD (T score < or = 0). Nineteen women were allocated to receive conjugated estrogens (0.625 mg/d orally) and 19 to receive a matching placebo. All continued with regular DMPA injections throughout the study. Areal bone density was measured by dual energy x-ray absorptiometry at the lumbar spine, femoral neck, and total body sites every 6 months for 2 yr; the main outcome measure being the change in areal BMD at the lumbar spine. At baseline, the two groups were well matched for demographic, anthropometric, and biochemical variables, and for BMD. Twenty-seven subjects completed at least 18 months in the study, and 26 the full 2 yr, with similar numbers dropping out from each group (mainly for personal reasons). In the estrogen-treated group, mean lumbar spine BMD increased 1%, whereas in the placebo group it fell 2.6%, over 2 yr. The between group differences were 2.0% at 12 months (P = 0.058), 3.2% at 18 months (P < 0.01), and 3.5% at 24 months (P < 0.002). Differences of lesser statistical magnitude were seen at the femoral neck (between group differences at 2 yr: 2.7%, P = 0.24), Ward's triangle (5.0%, P = 0.055), greater trochanter (3.6%, P = 0.056), total body (1.3%, P = 0.046), legs (1.3%, P = 0.065), and trunk (2.0%, P = 0.029). There were no major adverse events. These data support the view that the likely cause of DMPA-associated bone loss is estrogen deficiency and demonstrate that it can be arrested by estrogen replacement therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2002-020874

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Cundy, T., Ames, R., Horne, A., Clearwater, J., Roberts, H., Gamble, G., & Reid, I. R.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2003-01-01
Volume
88
Issue
1
Pages
78-81
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1974563897
Cited by
83
References
3
FWCI
4.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.