Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 428

The DOI matches its Crossref record.

Recombinant Human Thyrotropin-Stimulated Serum Thyroglobulin Combined with Neck Ultrasonography Has the Highest Sensitivity in Monitoring Differentiated Thyroid Carcinoma

Open access
Pacini, F., Molinaro, E., Castagna, M. G., Agate, L., Elisei, R., Ceccarelli, C., Lippi, F., Taddei, D., Grasso, L., Pinchera, A.·2003·The Journal of Clinical Endocrinology & Metabolism

Abstract

Recombinant human TSH (rhTSH)-stimulated thyroglobulin (Tg) measurement and (131)I whole body scan (WBS) have been validated as informative tests in the postsurgical follow-up of differentiated thyroid carcinoma. We report the diagnostic accuracy of Tg measurement and diagnostic WBS, alone or in combination, after rhTSH stimulation in a retrospective, consecutive series of patients undergoing follow-up for differentiated thyroid cancer. Routine procedures also include neck ultrasound in every patient and post-therapy WBS when indicated. We studied 340 consecutive patients with differentiated thyroid carcinoma, previously treated with near-total thyroidectomy and (131)I thyroid ablation, scheduled for routine diagnostic tests. At baseline on L-T(4)-suppressive therapy, 294 patients had undetectable (<1 ng/ml) serum Tg and negative anti-Tg autoantibodies (TgAb), 25 patients had undetectable serum Tg and positive TgAb, and 21 patients had detectable serum Tg and negative TgAb. These patients were tested for the presence of active disease by rhTSH stimulation. The results of our study showed that rhTSH-stimulated Tg alone had a diagnostic sensitivity of 85% for detecting active disease and a negative predictive value (NPV) of 98.2%. After adding the results of neck ultrasound, sensitivity increased to 96.3%, and the NPV to 99.5%. rhTSH-stimulated WBS had a sensitivity of only 21% and a NPV of 89%. The combination of rhTSH-stimulated Tg and WBS had a sensitivity of 92.7% and a NPV of 99%. We conclude that the rhTSH-stimulated Tg test combined with neck ultrasonography has the highest diagnostic accuracy in detecting persistent disease in the follow-up of differentiated thyroid carcinoma. A detectable level of serum Tg on L-T(4), its conversion from undetectable to detectable after rhTSH, and/or a suspicious finding at ultrasound will allow the identification of patients requiring therapeutic procedures without the need for diagnostic WBS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2002-021925

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 428

Metadata

Authors
Pacini, F., Molinaro, E., Castagna, M. G., Agate, L., Elisei, R., Ceccarelli, C., Lippi, F., Taddei, D., Grasso, L., & Pinchera, A.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2003-08
Volume
88
Issue
8
Pages
3668-3673
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2081487777
Cited by
428
References
0
FWCI
16.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recombinant Human Thyrotropin-Stimulated Serum Thyroglobulin Combined with Neck Ultrasonography Has the Highest Sensitivity in Monitoring Differentiated Thyroid Carcinoma. https://app.cochat.ai/papers/10.1210/jc.2002-021925
The paper
Pacini, F., Molinaro, E., Castagna, M. G., Agate, L., Elisei, R., Ceccarelli, C., Lippi, F., Taddei, D., Grasso, L., & Pinchera, A. (2003). Recombinant Human Thyrotropin-Stimulated Serum Thyroglobulin Combined with Neck Ultrasonography Has the Highest Sensitivity in Monitoring Differentiated Thyroid Carcinoma. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2002-021925

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.