Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 202

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of Methods to Measure Low Serum Estradiol Levels in Postmenopausal Women

Lee, Jennifer S., Ettinger, Bruce, Stanczyk, Frank Z., Vittinghoff, Eric, Hanes, Vladimir, Cauley, Jane A., Chandler, Walt, Settlage, Jim, Beattie, Mary S., Folkerd, Elizabeth, Dowsett, Mitch, Grady, Deborah, Cummings, Steven R. · 2006 · The Journal of Clinical Endocrinology & Metabolism

Abstract

CONTEXT: Accurate measurement of low serum estradiol (E(2) < 30 pg/ml or < 110 pmol/liter) is needed to study relationships between endogenous E(2) and risks of diseases in older women. OBJECTIVE: The objective of this study was to determine whether an extraction-based (indirect) assay or a non-extraction-based (direct) assay correlates better with mass spectrometry and body mass index (BMI). DESIGN/SETTING: In a pilot study of 40 postmenopausal women, endogenous E(2) measurements from three indirect and four direct assay methods and gas chromatography-tandem mass spectrometry (GC-MS/MS) were compared. A confirmatory study compared an indirect and a direct assay, selected among those in the pilot study, to GC-MS/MS; this study was conducted in 374 postmenopausal women not taking hormone therapy from the Ultra Low-dose TRansdermal estrogen Assessment (ULTRA) trial. MAIN OUTCOMES: Pearson correlation coefficients among E(2) measurements by assay methods and BMI, and their confidence intervals, by bias-corrected bootstrap method, were used. RESULTS: In the pilot study, E(2) by three indirect assays correlated better (P < 0.03) with GC-MS/MS and with BMI than measurements by four direct assays. In the confirmatory study, the indirect assay correlated better (P < 0.01) with GC-MS/MS and BMI than the direct assay. Measurements by the indirect and direct assays were overestimated, but deviations in direct assay measurements were less precise. Mean E(2) by the indirect and direct assays were higher (by 14 and 68%, respectively) and less reproducible than by GC-MS/MS. CONCLUSION: Until mass spectrometry is practical for wide use, extraction-based indirect assays may be preferable for measuring low postmenopausal serum E(2).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2005-2378

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 202

Metadata

Authors
Lee, J. S., Ettinger, B., Stanczyk, F. Z., Vittinghoff, E., Hanes, V., Cauley, J. A., Chandler, W., Settlage, J., Beattie, M. S., Folkerd, E., Dowsett, M., Grady, D., & Cummings, S. R.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2006-10-01
Volume
91
Issue
10
Pages
3791-3797
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2063712126
Cited by
202
References
1
FWCI
6.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.