CoChat

Comparison of Competitive Radioimmunoassays and Two-Site Sandwich Assays for the Measurement and Interpretation of Plasma Ghrelin Levels

Open access
Prudom, Catherine, Liu, Jianhua, Patrie, James, Gaylinn, Bruce D., Foster-Schubert, Karen E., Cummings, David E., Thorner, Michael O., Geysen, H. Mario · 2010 · The Journal of Clinical Endocrinology & Metabolism
Cited by 65

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Context: Ghrelin, an endogenous ligand for the GH secretagogue receptor, is an orexigenic peptide hormone produced primarily by the stomach. Recent studies suggest significant differences in the specificity of currently available ghrelin assays. Objective: The aim of the study was to compare four ghrelin assays (two commercially available and two developed by our group) of differing specificity, each used on the same set of more than 800 plasma samples from a human study. Design: Thirteen volunteers were sampled every 20 min for 6 h after consumption of one of three isocaloric drinks consisting of either 80% fat, 80% carbohydrate, or 80% protein. The samples were assayed by RIA for total and active ghrelin, as well as by sandwich assays for acyl and des-acyl ghrelin. The ghrelin profiles for each individual were smoothed using a statistical algorithm to lessen the effects of pulsatility and noise. Results: The sandwich assays for acyl and des-acyl ghrelin yielded ghrelin values that were lower than those from the corresponding RIAs. The ghrelin profiles after nutrient ingestion were similar, yet key differences among the four assays were apparent; in particular, percentage changes were significantly greater in the sandwich assays. Conclusions: The lower levels and greater relative changes in ghrelin values reported by the sandwich assays are consistent with greater assay specificity. When applied to the nutrient study, the sandwich assays were better able to distinguish the different responses to different nutrients than were the RIAs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2009-2407

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 65

Metadata

Authors
Prudom, C., Liu, J., Patrie, J., Gaylinn, B. D., Foster-Schubert, K. E., Cummings, D. E., Thorner, M. O., & Geysen, H. M.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2010-05-01
Volume
95
Issue
5
Pages
2351-2358
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1972638274
Cited by
65
References
3
FWCI
3.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Competitive Radioimmunoassays and Two-Site Sandwich Assays for the Measurement and Interpretation of Plasma Ghrelin Levels. https://app.cochat.ai/papers/10.1210/jc.2009-2407
The paper
Prudom, C., Liu, J., Patrie, J., Gaylinn, B. D., Foster-Schubert, K. E., Cummings, D. E., Thorner, M. O., & Geysen, H. M. (2010). Comparison of Competitive Radioimmunoassays and Two-Site Sandwich Assays for the Measurement and Interpretation of Plasma Ghrelin Levels. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2009-2407

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.