CoChat

Copeptin in the Differential Diagnosis of the Polydipsia-Polyuria Syndrome—Revisiting the Direct and Indirect Water Deprivation Tests

Fenske, Wiebke, Quinkler, Marcus, Lorenz, Daniela, Zopf, Kathrin, Haagen, Ulrike, Papassotiriou, Jana, Pfeiffer, Andreas F. H., Fassnacht, Martin, Störk, Stefan, Allolio, Bruno · 2011 · The Journal of Clinical Endocrinology & Metabolism
Cited by 184

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The water deprivation test (WDT) with direct or indirect measurement of plasma arginine vasopressin (AVP) is the method of choice for the differential diagnosis of the polydipsia-polyuria syndrome. In theory, direct measurement of AVP is highly attractive but is hampered by technical difficulties. OBJECTIVE: The aim of the study was to evaluate the utility of copeptin, a surrogate of AVP secretion, in the diagnostic work-up of the polyuria-polydipsia syndrome and to compare its performance with the current diagnostic standard. SETTING AND DESIGN: In two tertiary referral centers, 20 healthy subjects and 50 patients with polydipsia-polyuria syndrome underwent WDT with measurements of both plasma AVP and copeptin levels. The reference diagnosis was based on clinical information and treatment response. RESULTS: Twenty-two patients (44%) were diagnosed with primary polydipsia, 17 (34%) with partial central diabetes insipidus (DI), nine (18%) with complete central DI, and two (4%) with nephrogenic DI. The indirect WDT led to a correct diagnosis in 35 of 50 patients (70%). The direct WDT with AVP or copeptin measurement correctly diagnosed 23 patients (46%) or 36 patients (72%), respectively. Baseline copeptin values greater than 20 pmol/liter identified patients with nephrogenic DI, and concentrations below 2.6 pmol/liter indicated complete central DI. The ratio between Δ copeptin (0800 to 1600 h) and serum sodium concentration at 1600 h yielded optimal diagnostic accuracy, allowing us to also discern partial central DI from primary polydipsia (sensitivity 86%, and specificity 100%). CONCLUSION: Copeptin holds promise as a diagnostic tool in the polyuria-polydipsia syndrome, improving significantly the diagnostic accuracy of the direct WDT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2010-2345

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 184

Metadata

Authors
Fenske, W., Quinkler, M., Lorenz, D., Zopf, K., Haagen, U., Papassotiriou, J., Pfeiffer, A. F. H., Fassnacht, M., Störk, S., & Allolio, B.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2011-05
Volume
96
Issue
5
Pages
1506-1515
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1968534925
Cited by
184
References
6
FWCI
6.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Copeptin in the Differential Diagnosis of the Polydipsia-Polyuria Syndrome—Revisiting the Direct and Indirect Water Deprivation Tests. https://app.cochat.ai/papers/10.1210/jc.2010-2345
The paper
Fenske, W., Quinkler, M., Lorenz, D., Zopf, K., Haagen, U., Papassotiriou, J., Pfeiffer, A. F. H., Fassnacht, M., Störk, S., & Allolio, B. (2011). Copeptin in the Differential Diagnosis of the Polydipsia-Polyuria Syndrome—Revisiting the Direct and Indirect Water Deprivation Tests. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2010-2345

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.