The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
The Effect of Insulin Feedback on Closed Loop Glucose Control
Open accessAbstract
CONTEXT: Initial studies of closed-loop proportional integral derivative control in individuals with type 1 diabetes showed good overnight performance, but with breakfast meal being the hardest to control and requiring supplemental carbohydrate to prevent hypoglycemia. OBJECTIVE: The aim of this study was to assess the ability of insulin feedback to improve the breakfast-meal profile. DESIGN AND SETTING: We performed a single center study with closed-loop control over approximately 30 h at an inpatient clinical research facility. PATIENTS: Eight adult subjects with previously diagnosed type 1 diabetes participated. INTERVENTION: Subjects received closed-loop insulin delivery with supplemental carbohydrate as needed. MAIN OUTCOME MEASURES: Outcome measures were plasma insulin concentration, model-predicted plasma insulin concentration, 2-h postprandial and 3- to 4-h glucose rate-of-change following breakfast after 1 d of closed-loop control, and the need for supplemental carbohydrate in response to nadir hypoglycemia. RESULTS: Plasma insulin levels during closed loop were well correlated with model predictions (R = 0.86). Fasting glucose after 1 d of closed loop was not different from nighttime target (118 ± 9 vs. 110 mg/dl; P = 0.38). Two-hour postbreakfast glucose was 132 ± 16 mg/dl with stable values 3-4 h after the meal (0.03792 ± 0.0884 mg/dl · min, not different from 0; P = 0.68) and at target (97 ± 6 mg/dl, not different from 90; P = 0.28). Three subjects required supplemental carbohydrates after breakfast on d 2 of closed loop. CONCLUSIONS/INTERPRETATION: Insulin feedback can be implemented using a model estimate of concentration. Proportional integral derivative control with insulin feedback can achieve a desired breakfast response but still requires supplemental carbohydrate to be delivered in some instances. Studies assessing more optimal control configurations and safeguards need to be conducted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A model of the kinetics of insulin in man
Sherwin, R. S., Kramer, K. J., Tobin, J. D., Insel, P. A., Liljenquist, J. E., Berman, M., & Andres, R. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107697 · Cited by 460 · cited 1×
“The present study assessed the ability of an insulin PK model (13) to predict the plasma insulin profile obtained with sc insulin delivery and whether feedback of the profile would allow acceptable closed-loop meal responses to be obtained in humans.”
MethodClarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Elahi, D. (1996) · Diabetes Care · doi:10.2337/diacare.19.3.278 · Cited by 168
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Self-citation
Cited by
Outpatient Glycemic Control with a Bionic Pancreas in Type 1 Diabetes
Russell, S. J., El-Khatib, F. H., Sinha, M., Magyar, K. L., McKeon, K., Goergen, L. G., Balliro, C., Hillard, M. A., Nathan, D. M., & Damiano, E. R. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1314474 · Cited by 602
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585
“Medtronic systems have been under development for several years.(19) Feasibility or preliminary studies in clinical settings,(20) at camp,(21) in hotel,(22) and in supervised outpatient settings(23) have been carried out to evaluate the robustness of the Medtronic control algorithm, including the system’s response to…”
MethodSelf-citationClosed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
The artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
McAuley, S. A., Lee, M. H., Paldus, B., Vogrin, S., de Bock, M. I., Abraham, M. B., Bach, L. A., Burt, M. G., Cohen, N. D., Colman, P. G., et al. (2020) · Diabetes Care · doi:10.2337/dc20-1447 · Cited by 158
Metadata
- Authors
- Steil, G. M., Palerm, C. C., Kurtz, N., Voskanyan, G., Roy, A., Paz, S., & Kandeel, F. R.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2011-05
- Volume
- 96
- Issue
- 5
- Pages
- 1402-1408
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W1971476108
- Cited by
- 195
- References
- 4
- FWCI
- 15.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Insulin Feedback on Closed Loop Glucose Control. https://app.cochat.ai/papers/10.1210/jc.2010-2578
- The paper
- Steil, G. M., Palerm, C. C., Kurtz, N., Voskanyan, G., Roy, A., Paz, S., & Kandeel, F. R. (2011). The Effect of Insulin Feedback on Closed Loop Glucose Control. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2010-2578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.