Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Thyroglobulin Is a Sensitive Measure of Both Deficient and Excess Iodine Intakes in Children and Indicates No Adverse Effects on Thyroid Function in the UIC Range of 100–299 μg/L: A UNICEF/ICCIDD Study Group Report

Zimmermann, Michael B., Aeberli, Isabelle, Andersson, Maria, Assey, Vincent, Yorg, Jorge A. Jara, Jooste, Pieter, Jukić, Tomislav, Kartono, Djoko, Kusić, Zvonko, Pretell, Eduardo, San Luis, Teofilo O. L., Untoro, Juliawati, Timmer, Arnold · 2013 · The Journal of Clinical Endocrinology & Metabolism

Abstract

CONTEXT: The median urinary iodine concentration (UIC) is a biomarker of iodine intake. According to the World Health Organization, a median UIC in the range 100-199 μg/L indicates adequate and 200-299 μg/L more than adequate intake. Thyroglobulin (Tg) may be a promising functional biomarker of both iodine deficiency and excess. OBJECTIVES: Using a standardized dried blood spots-Tg assay in children, we evaluated the Tg response to both low- and high-iodine intake and estimated the population cutoff point for iodine deficiency or excess. Also, we compared thyroid functions within the UIC ranges of 100-199 vs 200-299 μg/L. DESIGN AND SETTING: We conducted a cross-sectional study in primary schools in 12 countries. SUBJECTS: SUBJECTS were 6 to 12 years old (n = 2512). MAIN OUTCOME MEASURES: We measured UIC, TSH, total T4, Tg, and thyroid antibodies. RESULTS: Over a range of iodine intakes from severely deficient to excessive, Tg concentrations showed a clear U-shaped curve. Compared with iodine-sufficient children, there was a significantly higher prevalence of elevated Tg values in children with iodine deficiency (UIC <100 μg/L) and iodine excess (UIC >300 μg/L). There was no significant change in the prevalence of elevated Tg, TSH, T4, or thyroid antibodies comparing children within the UIC ranges of 100-199 vs 200-299 μg/L. CONCLUSIONS: In school-aged children, 1) Tg is a sensitive indicator of both low and excess iodine intake; 2) a median Tg of <13 μg/L and/or <3% of Tg values >40 μg/L indicates iodine sufficiency in the population; 3) the acceptable range of median UIC in monitoring iodized salt programs could be widened to a single category of sufficient iodine intake from 100 to 299 μg/L.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2012-3952

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Zimmermann, M. B., Aeberli, I., Andersson, M., Assey, V., Yorg, J. A. J., Jooste, P., Jukić, T., Kartono, D., Kusić, Z., Pretell, E., San Luis, T. O. L., Untoro, J., & Timmer, A.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2013-03-01
Volume
98
Issue
3
Pages
1271-1280
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2166674184
Cited by
210
References
5
FWCI
14.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.