Iodine-Induced Hypothyroidism in Full-term Infants With Congenital Heart Disease: More Common Than Currently Appreciated?
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Context: Iodine is a micronutrient essential for thyroid hormone synthesis. Thyroid hormone is critical for normal neurocognitive development in young infants, and even transient hypothyroidism can cause adverse neurodevelopmental outcomes. Both iodine deficiency and excess can cause hypothyroidism. Although iodine-induced hypothyroidism is well recognized in premature infants, full-term neonates have received less attention. Infants with congenital heart disease (CHD) are commonly exposed to excess iodine from administration of iodinated contrast agents during cardiac catheterization as well as topical application of iodine-containing antiseptics and dressings; hence, this is a vulnerable population. Objective: We report three cases of iodine-induced hypothyroidism in full-term neonates with CHD after cardiac angiography and topical application of iodine-containing antiseptics and dressings in the operative setting. Results: Three neonates with CHD and normal thyroid function at birth developed hypothyroidism after exposure to excess iodine. Two of these infants had transient hypothyroidism, and one had severe hypothyroidism requiring ongoing thyroid replacement therapy. All infants were asymptomatic, with hypothyroidism detected incidentally in the inpatient setting due to repeat newborn screening mandated by the long duration of hospitalization in these infants. Conclusions: Iodine-induced hypothyroidism may be under-recognized in infants with CHD exposed to excess iodine. Systematic monitoring of thyroid function should be considered to avoid potential long-term adverse neurodevelopmental effects of even transient thyroid dysfunction in this susceptible population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marino, B. S., Lipkin, P. H., Newburger, J. W., Peacock, G., Gerdes, M., Gaynor, J. W., Mussatto, K. A., Uzark, K., Goldberg, C. S., Johnson, W. H., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318265ee8a · Cited by 1,608
The role of glucocorticoids in the regulation of thyroid function in man
Nicoloff, J. T., Fisher, D. A., & Appleman, M. D. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106411 · Cited by 261
Rhee, C. M. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.677 · Cited by 222
Oerbeck, B., Sundet, K., Kase, B. F., & Heyerdahl, S. (2003) · Pediatrics · doi:10.1542/peds.112.4.923 · Cited by 176
Congenital Hypothyroidism Caused by Excess Prenatal Maternal Iodine Ingestion
Connelly, K. J., Boston, B. A., Pearce, E. N., Sesser, D., Snyder, D., Braverman, L. E., Pino, S., & LaFranchi, S. H. (2012) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2012.05.057 · Cited by 136 · cited 1×
“Less frequent causes of iodine-induced hypothyroidism include direct ingestion of breast milk containing high iodine levels (8, 9) and iv administration of iodine-containing radiological contrast agents (10 –13).”
BackgroundSelf-citationMitchell, M. L., Hsu, H.-W., Sahai, I., & and the Massachusetts Pediatric Endocrine Work Group (2011) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2011.04128.x · Cited by 117
Cited by
Alexander, E. K., Pearce, E. N., Brent, G. A., Brown, R. S., Chen, H., Dosiou, C., Grobman, W. A., Laurberg, P., Lazarus, J. H., Mandel, S. J., et al. (2017) · Thyroid® · doi:10.1089/thy.2016.0457 · Cited by 2,731
“In addition, iodine-induced hypothyroidism has been reported in infants exposed to excess iodine from radiocontrast agents (136).”
BackgroundSelf-citationA Review: Radiographic Iodinated Contrast Media-Induced Thyroid Dysfunction
Lee, S. Y., Rhee, C. M., Leung, A. M., Braverman, L. E., Brent, G. A., & Pearce, E. N. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-3292 · Cited by 221
Self-citationHypothyroidism in Infants With Congenital Heart Disease Exposed to Excess Iodine
Thaker, V. V., Galler, M. F., Marshall, A. C., Almodovar, M. C., Hsu, H.-W., Addis, C. J., Feldman, H. A., Brown, R. S., & Levine, B.-S. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00174 · Cited by 48
Self-citation
Metadata
- Authors
- Thaker, V. V., Leung, A. M., Braverman, L. E., Brown, R. S., & Levine, B.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2014-10-01
- Volume
- 99
- Issue
- 10
- Pages
- 3521-3526
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2164929953
- Cited by
- 50
- References
- 6
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.