CoChat

Label-free Intraoperative Parathyroid Localization With Near-Infrared Autofluorescence Imaging

Open access
McWade, Melanie A., Paras, Constantine, White, Lisa M., Phay, John E., Solórzano, Carmen C., Broome, James T., Mahadevan-Jansen, Anita · 2014 · The Journal of Clinical Endocrinology & Metabolism
Cited by 182

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

CONTEXT: The inability to accurately localize the parathyroid glands during parathyroidectomy and thyroidectomy procedures can prevent patients from achieving postoperative normocalcemia. There is a critical need for an improved intraoperative method for real-time parathyroid identification. OBJECTIVE: The objective of the study was to test the accuracy of a real-time, label-free technique that uses near-infrared (NIR) autofluorescence imaging to localize the parathyroid. SETTING: The study was conducted at the Vanderbilt University endocrine surgery center. SUBJECTS AND METHODS: Patients undergoing parathyroidectomy and/or thyroidectomy were included in this study. To validate the intrinsic fluorescence signal in parathyroid, point measurements from 110 patients were collected using NIR fluorescence spectroscopy. Fluorescence imaging was performed on 6 patients. Imaging contrast is based on a previously unreported intrinsic NIR fluorophore in the parathyroid gland. The accuracy of fluorescence imaging was analyzed in comparison with visual assessment and histological findings. MAIN OUTCOME MEASURE: The detection rate of parathyroid glands was measured. RESULTS: The parathyroid glands in 100% of patients measured with fluorescence imaging were successfully detected in real time. Fluorescence images consistently showed 2.4 to 8.5 times higher emission intensity from the parathyroid than surrounding tissue. Histological validation confirmed that the high intrinsic fluorescence signal in the parathyroid gland can be used to localize the parathyroid gland regardless of disease state. CONCLUSION: NIR fluorescence imaging represents a highly sensitive, real-time, label-free tool for parathyroid localization during surgery. The elegance and effectiveness of NIR autofluorescence imaging of the parathyroid gland makes it highly attractive for clinical application in endocrine surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2014-2503

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 182

Metadata

Authors
McWade, M. A., Paras, C., White, L. M., Phay, J. E., Solórzano, C. C., Broome, J. T., & Mahadevan-Jansen, A.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2014-12
Volume
99
Issue
12
Pages
4574-4580
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2157478648
Cited by
182
References
15
FWCI
5.08
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Label-free Intraoperative Parathyroid Localization With Near-Infrared Autofluorescence Imaging. https://app.cochat.ai/papers/10.1210/jc.2014-2503
The paper
McWade, M. A., Paras, C., White, L. M., Phay, J. E., Solórzano, C. C., Broome, J. T., & Mahadevan-Jansen, A. (2014). Label-free Intraoperative Parathyroid Localization With Near-Infrared Autofluorescence Imaging. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2014-2503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.