Continuous Glucose Monitoring and its Relationship to Hemoglobin A1c and Oral Glucose Tolerance Testing in Obese and Prediabetic Youth
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
CONTEXT: The optimal screening test for diabetes and prediabetes in obese youth is controversial. OBJECTIVE: We examined whether glycosylated hemoglobin (HbA1c) or the oral glucose tolerance test (OGTT) is a better predictor of free-living glycemia as measured by continuous glucose monitoring (CGM). DESIGN: This was a cross-sectional study of youth 10-18 years old, body mass index (BMI) 85th percentile or greater, with diabetes risk factors. SETTING AND PARTICIPANTS: Participants (n = 118) with BMI 85th percentile or greater, not on medications for glucose management, were recruited from primary care and pediatric endocrinology clinics around Denver, Colorado. INTERVENTION: HbA1c, fasting plasma glucose, and 2-hour glucose were collected and all participants wore a blinded CGM for 72 hours. MAIN OUTCOME MEASURES: CGM outcomes were determined and descriptive statistics calculated. Performance characteristics at current American Diabetes Association cutpoints were compared with CGM outcomes. RESULTS: CGM data were successfully collected on 98 obese youth. Those with prediabetes had significantly higher average glucose, area under the curve (AUC), peak glucose, and time greater than 120 and greater than 140 mg/dL (P < .01) on CGM than youth with normal HbA1c or OGTT. HbA1c had a greater magnitude of correlation to CGM average glucose, AUC, and minimum glucose; 2-hour glucose had a greater magnitude of correlation to CGM SD, peak glucose, and time greater than 140 and greater than 200 mg/dL. However, there were no overall differences in the strength comparisons between 2-hour glucose and HbA1c correlations to CGM outcomes. CONCLUSIONS: In obese youth, HbA1c and 2-hour glucose performed equally well at predicting free-living glycemia on CGM, suggesting that both are valid tests for dysglycemia screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of Childhood and Adult Obesity in the United States, 2011-2012
Ogden, C. L., Carroll, M. D., Kit, B. K., & Flegal, K. M. (2014) · JAMA · doi:10.1001/jama.2014.732 · Cited by 8,072
International Expert Committee report on the role of the A1c assay in the diagnosis of diabetes
The International Expert Committee (2009) · Diabetes Care · doi:10.2337/dc09-9033 · Cited by 3,185
Cowie, C. C., Rust, K. F., Byrd-Holt, D. D., Gregg, E. W., Ford, E. S., Geiss, L. S., Bainbridge, K. E., & Fradkin, J. E. (2010) · Diabetes Care · doi:10.2337/dc09-1524 · Cited by 689
Glucose Variability; Does It Matter?
Siegelaar, S. E., Holleman, F., Hoekstra, J. B. L., & DeVries, J. H. (2010) · Endocrine Reviews · doi:10.1210/er.2009-0021 · Cited by 409
Type 2 Diabetes in Youth: Epidemiology and Pathophysiology
D’Adamo, E., & Caprio, S. (2011) · Diabetes Care · doi:10.2337/dc11-s212 · Cited by 315
Screening for Diabetes and Pre-Diabetes With Proposed A1C-Based Diagnostic Criteria
Olson, D. E., Rhee, M. K., Herrick, K., Ziemer, D. C., Twombly, J. G., & Phillips, L. S. (2010) · Diabetes Care · doi:10.2337/dc10-0433 · Cited by 255
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1971 · Cited by 138
Cited by
Arslanian, S., Bacha, F., Grey, M., Marcus, M. D., White, N. H., & Zeitler, P. (2018) · Diabetes Care · doi:10.2337/dci18-0052 · Cited by 349
“Studies using continuous glucose monitoring (CGM) in youth with obesity demonstrated that A1C and OGTT are equally effective at identifying glycemic abnormalities on CGM, but the glycemic patterns differ (57); abnormal A1C was associated with higher overall and nighttime average glucose on CGM, while abnormal OGTT was…”
BackgroundSelf-citationChesser, H., Srinivasan, S., Puckett, C., Gitelman, S. E., & Wong, J. C. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221139873 · Cited by 40
“Prior work on CGM in AYAs with T2D has focused only on the clinician’s retrospective review of CGM data to provide medication recommendations, describe glycemic variability, or assist in diagnosis, 4,25,26 while self-review by adolescents with T2D or their caregivers has yet to be described.”
Moody, E. C., Cantoral, A., Tamayo-Ortiz, M., Pizano-Zárate, M. L., Schnaas, L., Kloog, I., Oken, E., Coull, B., Baccarelli, A., Téllez-Rojo, M. M., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.17643 · Cited by 27
Metadata
- Authors
- Chan, C. L., Pyle, L., Newnes, L., Nadeau, K. J., Zeitler, P. S., & Kelsey, M. M.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2015-03
- Volume
- 100
- Issue
- 3
- Pages
- 902-910
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W1980598889
- Cited by
- 70
- References
- 7
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.