CoChat

Insulin autoantibodies measured by radioimmunoassay methodology are more related to insulin-dependent diabetes mellitus than those measured by enzyme-linked immunosorbent assay: results of the Fourth International Workshop on the Standardization of Insulin Autoantibody Measurement

Open access
Greenbaum, C. J. · 1992 · Journal of Clinical Endocrinology & Metabolism
Cited by 156

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Insulin autoantibodies (IAA) have been identified in newly diagnosed insulin-dependent diabetes mellitus (IDDM) patients and in individuals at high risk of developing the disease. However, the literature is not in agreement regarding the prevalence, significance, and predictive value of IAA. Previous workshops have shown that certain sera give markedly different results depending upon assay methodology and, therefore, have suggested that these discrepancies may be due to variations in the assay methodologies used: either the fluid phase RIA or the solid phase enzyme-linked immunosorbent assay (ELISA). Sera from controls (n = 61), newly diagnosed IDDM patients (n = 30), healthy subjects who later became diabetic (n = 8), and first degree relatives of diabetic probands (n = 22) were randomly numbered and sent without category identification to 19 RIA and 10 ELISA laboratories. Each laboratory's raw data from the control sera were used to determine the cut-off point for positive (3 SD above the mean of control sera) in the disease relevant categories. RIA and ELISA methods were comparable in obtaining a low frequency of IAA in control sera. However, the laboratories using RIA methods found a much higher percentage of sera to be IAA positive among both newly diagnosed patients and healthy individuals who later developed diabetes than laboratories using ELISA methods (P less than 0.005). In contrast, there was considerable overlap in the percentage of sera from first degree relatives found positive by both assays. These data strongly suggest that IAA measured by RIA methodology are more disease related than those measured by ELISA methods. Consequently, RIA assays or assays proven to perform as well should be used to measure IAA associated with IDDM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.74.5.1040

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 156

Metadata

Authors
Greenbaum, C. J.
Venue
Journal of Clinical Endocrinology & Metabolism
Published
1992-05-01
Volume
74
Issue
5
Pages
1040-1044
ISSN
0021-972X (ISSN-L)
OpenAlex
W2076475992
Cited by
156
References
1
FWCI
3.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.