Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 362

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Assessment of the serum levels of bone alkaline phosphatase with a new immunoradiometric assay in patients with metabolic bone disease

Garnero, P.·1993·Journal of Clinical Endocrinology & Metabolism

Abstract

We measured serum bone alkaline phosphatase (B-ALP) with a new immunoradiometric assay (IRMA) in a large sample of healthy controls comprising 173 women and 180 men, 20-88 yr of age, and in patients with metabolic bone disease. Using serum samples from patients with liver disease and patients with Paget's disease with elevated total alkaline phosphatase (T-ALP) as a source of, respectively, liver and bone isoenzymes, we determined a liver cross-reactivity of the IRMA of 16% that was confirmed by electrophoresis of the circulating alkaline phosphatase isoenzymes. The IRMA was linear for serial sample dilutions, the recovery ranged from 89-110%, and the intra- and interassay variations were below 7% and 9%, respectively. B-ALP increased linearly with age in both sexes, and the mean B-ALP serum levels were not significantly different for women and men (11.3 +/- 4.8 ng/mL for women; 11.0 +/- 4.0 ng/mL for men). The increase in B-ALP after the menopause was significantly higher than that in T-ALP (+77% vs. +24%; P < 0.001). When the values of postmenopausal women were expressed as the SD from the mean of premenopausal women, the mean Z scores were 2.2 +/- 1.8 for B-ALP and 0.9 +/- 1.3 for T-ALP (P < 0.001 between the two). Serum B-ALP was increased from control values in patients with Paget's disease (n = 57; mean, 171.8 +/- 135.6 ng/mL; P < 0.001), in patients with primary hyperparathyroidism (n = 18; mean, 17.2 +/- 5.9 ng/mL; P < 0.001), and in patients with chronic renal failure on hemodialysis (n = 83; mean, 36.6 +/- 35.7 ng/mL; P < 0.001). In patients with Paget's disease, B-ALP was highly correlated with T-ALP (r2 = 0.94; P < 0.001), and the decrease in its serum level was larger than that in T-ALP after treatment with the bisphosphonate pamidronate (-58% vs. -43%; P < 0.03). In patients with various liver diseases, B-ALP was slightly increased, but stayed within the normal range (mean +/- 2 SD) until T-ALP did not exceed 4.5 mu katal/L. We conclude that this new IRMA for B-ALP is reliable, has a low cross-reactivity with the liver isoenzyme, and appears to be more sensitive than T-ALP for the clinical investigation of patients with osteoporosis and other metabolic bone diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.77.4.1046

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 362

Metadata

Authors
Garnero, P.
Venue
Journal of Clinical Endocrinology & Metabolism
Published
1993-10-01
Volume
77
Issue
4
Pages
1046-1053
ISSN
0021-972X (ISSN-L)
OpenAlex
W2002764204
Cited by
362
References
17
FWCI
15.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of the serum levels of bone alkaline phosphatase with a new immunoradiometric assay in patients with metabolic bone disease. https://app.cochat.ai/papers/10.1210/jc.77.4.1046
The paper
Garnero, P. (1993). Assessment of the serum levels of bone alkaline phosphatase with a new immunoradiometric assay in patients with metabolic bone disease. Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.77.4.1046

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.