CoChat

The use of recombinant human thyrotropin produced by Chinese hamster ovary cells for the preparation of immunoassay reagents

Ribela, M. T. · 1996 · Journal of Clinical Endocrinology & Metabolism
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Recombinant human TSH (rec-hTSH; Thyrogen, lot M-17073) obtained from transformed Chinese hamster ovary cells was tested for both radioiodination and preparation of a secondary standard used in RIA and immunoradiometric assay (IRMA) for routine clinical investigation. Results were compared to those obtained with high quality pituitary TSH (pit-hTSH; Dr. P. Torjesen, Oslo, Norway; and NIDDK, Rockville, MD), traditionally used in these assays. After extensive characterization and testing, it was found that [125I]rec-hTSH matched all binding and chromatographic criteria usually obtained with [125I]pit-hTSH, including Stokes' radius, labeling, and storage stability, and did not introduce any significant bias when used in the measurement of unknown serum samples. A preparation of rec-hTSH was calibrated against a local secondary standard as well as against two well known international reference preparations (NIDDK hTSH RP-1 and WHO International Reference Preparation 80/558) by IRMA and RIA. In the RIA, NIDDK anti-hTSH-3 polyclonal antibody was used, whereas in the IRMA, two commercial preparations were used: a monoclonal antibody as the detecting antibody, and a polyclonal antibody as the capture antibody. In both assays, the recombinant standard preparation yielded good fit displacement curves, showing significant parallelism compared to pit-hTSH and therefore allowing an unbiased measurement of unknown serum samples. The specific activity of the rec-hTSH preparation calibrated against the WHO International Reference Preparation was 7.7 IU/mg protein when measured by IRMA and 7.1 IU/mg when measured by RIA. In conclusion, these results indicate for the first time that rec-hTSH can fully replace pit-hTSH as both standard and tracer in diagnostic in vitro systems such as RIA and IRMA, suggesting that other recombinant glycosylated hormones might also serve for immunoassay reagent preparation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.81.1.249

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 51

Metadata

Authors
Ribela, M. T.
Venue
Journal of Clinical Endocrinology & Metabolism
Published
1996-01-01
Volume
81
Issue
1
Pages
249-256
ISSN
0021-972X (ISSN-L)
OpenAlex
W2001206239
Cited by
51
References
2
FWCI
1.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The use of recombinant human thyrotropin produced by Chinese hamster ovary cells for the preparation of immunoassay reagents. https://app.cochat.ai/papers/10.1210/jc.81.1.249
The paper
Ribela, M. T. (1996). The use of recombinant human thyrotropin produced by Chinese hamster ovary cells for the preparation of immunoassay reagents. Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.81.1.249

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.