Laboratory and Clinical Experience in 55 Patients with Macroprolactinemia Identified by a Simple Polyethylene Glycol Precipitation Method
Open accessThe DOI matches its Crossref record.
Abstract
PRL exists in different forms in human serum. The predominant form is little PRL (molecular mass 23 kDa) with smaller amounts of big PRL (molecular mass 50--60 kDa) and at times big big or macroprolactin (molecular mass 150--170 kDa). The frequency and clinical consequences of macroprolactinemia have not been clearly established, mainly because of difficulty in identifying these patients biochemically. This previously required the use of gel filtration chromatography, which could not be used routinely. Recently, a screening test using polyethylene glycol (PEG) has been used to identify macroprolactin in serum. Consequently, this study was designed to examine the use of PEG precipitation in the identification of patients with a predominance of macroprolactin and to establish the clinical characteristics of such a cohort. Over 12 months, 18,258 requests for serum PRL were received and of these 1225 patients had a serum PRL more than 700 mU/L. A total of 322 of these patients (26%) had a percentage recovery after PEG precipitation of less than 40%, thus indicating the presence of a predominance of macroprolactin. Fifty-five of these patients were referred for detailed clinical assessment. Symptoms typical of hyperprolactinemia were not common in this cohort. None had sustained amenorrhea and eight have had oligomenorrhea at age less than 40 yr. One had galactorrhea. All had pituitary imaging, and four had a microadenoma with none having a macroadenoma. PEG precipitation allows easy identification of macroprolactin in routine clinical practice. As the clinical consequences of this entity at this stage seem relatively benign, referral and intensive investigation of these patients may not be necessary. However, follow-up of a large cohort is required to ensure that the long-term outlook is likewise benign. This would have important implications for both patients and healthcare systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interferences With Thyroid Function Immunoassays: Clinical Implications and Detection Algorithm
Favresse, J., Burlacu, M.-C., Maiter, D., & Gruson, D. (2018) · Endocrine Reviews · doi:10.1210/er.2018-00119 · Cited by 258
The epidemiology, diagnosis and treatment of Prolactinomas: The old and the new
Chanson, P., & Maiter, D. (2019) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2019.101290 · Cited by 237
Suliman, A. M., Smith, T. P., Gibney, J., & McKenna, T. J. (2003) · Clinical Chemistry · doi:10.1373/49.9.1504 · Cited by 177
The Impact on Clinical Practice of Routine Screening for Macroprolactin
Gibney, J., Smith, T. P., & McKenna, T. J. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-2234 · Cited by 159
Variability in the detection of macro TSH in different immunoassay systems
Hattori, N., Ishihara, T., & Shimatsu, A. (2016) · European Journal of Endocrinology · doi:10.1530/eje-15-0883 · Cited by 57
Metadata
- Authors
- Leslie, H.
- Venue
- Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2001-06-01
- Volume
- 86
- Issue
- 6
- Pages
- 2743-2746
- ISSN
- 0021-972X (ISSN-L)
- OpenAlex
- W2078524862
- Cited by
- 177
- References
- 0
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laboratory and Clinical Experience in 55 Patients with Macroprolactinemia Identified by a Simple Polyethylene Glycol Precipitation Method. https://app.cochat.ai/papers/10.1210/jc.86.6.2743
- The paper
- Leslie, H. (2001). Laboratory and Clinical Experience in 55 Patients with Macroprolactinemia Identified by a Simple Polyethylene Glycol Precipitation Method. Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.86.6.2743
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.