Contribution of Methodological Artifacts to the Measurement of T3Concentration in Serum
The DOI matches its Crossref record.
Abstract
Sources of artifactual error have been studied during the measurement of serum T8 using a commonly employed paper chromatographic method. Significant and variable artifactual elevation of the serum T3 concentration can result from solvents used in the method, from material eluted from the initial Dowex AG 50 resin or from Whatman chromatographic paper. The mechanism of this “blank” effect is not clear, but it is a problem common to all protein binding hormone assays. In addition, spillover of T4 into the T3 area of the paper chromatogram may occur, particularly if the serum extract is applied to wet paper. Since T4 displaces 2.5 times more labeled T3 from TBG than does an equivalent weight of T3, the effect of this T4 spillover will be magnified 2–3 times. The most important source of error is artifactual deiodination of T4 and the major radioactive product of the deiodination of 131I-T4 is iodide. However, a significant monodeiodination of T4 to T3 also occurs; over a several-month period, the radioactivity recovered as T3 after chromatography of purified 131I-T4 averaged about 0.7%. Such deiodination can be minimized by using wet paper, but the separation of T4 and T3 is less adequate under these circumstances. Presently available evidence would suggest that minimizing or correcting for these sources of artifact reduces the mean serum T3 concentration in euthyroid subjects to the range of 100–125 ng/100 ml.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surks, M. I., Schadlow, A. R., & Oppenheimer, J. H. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107137 · Cited by 188
Triiodothyronine Radioimmunoassay
Lieblich, J., & Utiger, R. D. (1972) · Journal of Clinical Investigation · doi:10.1172/jci106786 · Cited by 128
Radioimmunassay for measurement of triiodothyronine in human serum
Chopra, I. J., Solomon, D. H., & Beall, G. N. (1971) · Journal of Clinical Investigation · doi:10.1172/jci106696 · Cited by 119
Hollander, C., Mitsuma, T., Nihei, N., Shenkman, L., Zane Burday, S., & Blum, M. (1972) · The Lancet · doi:10.1016/s0140-6736(72)90408-4 · Cited by 61
Thyroid function tests and their alterations by drugs
Chopra, I. J., & Solomon, D. H. (1976) · Pharmacology & Therapeutics. Part C: Clinical Pharmacology and Therapeutics · doi:10.1016/s0362-5486(76)80026-x
Metadata
- Authors
- FISHER, D. A., & DUSSAULT, J. H.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1971-05
- Volume
- 32
- Issue
- 5
- Pages
- 675-679
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2001285049
- Cited by
- 36
- References
- 0
- FWCI
- 13.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contribution of Methodological Artifacts to the Measurement of T3Concentration in Serum. https://app.cochat.ai/papers/10.1210/jcem-32-5-675
- The paper
- FISHER, D. A., & DUSSAULT, J. H. (1971). Contribution of Methodological Artifacts to the Measurement of T3Concentration in Serum. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-32-5-675
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.