Plasma Cortisone Concentration as Measured by Radioimmunoassay
The DOI matches its Crossref record.
Abstract
A radioimmunoassay for measurement of cortisone in plasma has been developed utilizing rabbit anti-sera against a cortisone-bovine serum albumin complex. To insure specificity thin layer chromatography was used because unchromatographed samples resulted in 10–20% higher values than the chromatographed, even though the cross reactivity with cortisol was only 0.68% and with corticosterone 1.15%. The sensitivity of the assay varies 50–79 pg with recovery of cortisone added to plasma found to be 94.2 ± 5.8 (sd). The mean morning plasma level of cortisone in young men was 2.6 μg/100 ml ± 0.5 (sd) and in women 1.96 ± 0.54. Evening levels decreased in relation to cortisol concentration. Pregnant women had elevation of cortisone levels comparable to that of cortisol. After dexamethasone suppression plasma cortisone levels decreased but following ACTH and usually during acute stress there were no significant changes noted. In patients with severe liver disease cortisone concentration tended to be lower than normal but directly proportional to cortisol levels whereas in patients with kidney disease cortisone concentration was subnormal. Two patients with Cushing's syndrome had elevated levels of cortisone comparable to cortisol but after o,p′DDD therapy the concentration of cortisone decreased disproportionately thus suggesting an inhibitory effect by the drug on conversion of cortisol to cortisone. The results indicate that circulating cortisone is formed mainly in peripheral tissues with the kidney being a major source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DUNN, J. F., NISULA, B. C., & RODBARD, D. (1981) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-53-1-58 · Cited by 1,238
11β-Hydroxysteroid dehydrogenase type 1: a tissue specific regulator of glucocorticoid response
Tomlinson, J. W., Walker, E. A., Bujalska, I. J., Draper, N., Lavery, G. G., Cooper, M. S., Hewison, M., & Stewart, P. M. (2004) · Endocrine Reviews · doi:10.1210/er.2003-0031 · Cited by 969
“Isotopic studies (22) and clinical studies measuring F/E levels in patients with renal disease (23, 24) confirmed that the kidney was an important site for cortisol to cortisone conversion.”
11β-Hydroxysteroid Dehydrogenase
Stewart, P. M., & Krozowski, Z. S. (1997) · Vitamins & Hormones · doi:10.1016/s0083-6729(08)60646-9 · Cited by 718
Syndrome of apparent mineralocorticoid excess. A defect in the cortisol-cortisone shuttle.
Stewart, P. M., Corrie, J. E., Shackleton, C. H., & Edwards, C. R. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113592 · Cited by 430
11β-Hydroxysteroid dehydrogenase and the pre-receptor regulation of corticosteroid hormone action
Draper, N., & Stewart, P. M. (2005) · Journal of Endocrinology · doi:10.1677/joe.1.06019 · Cited by 375
Metadata
- Authors
- SRIVASTAVA, L. S., WERK, E. E., THRASHER, K., SHOLITON, L. J., KOZERA, R., NOLTEN, W., & KNOWLES, H. C.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1973-05
- Volume
- 36
- Issue
- 5
- Pages
- 937-943
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2068549711
- Cited by
- 47
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma Cortisone Concentration as Measured by Radioimmunoassay. https://app.cochat.ai/papers/10.1210/jcem-36-5-937
- The paper
- SRIVASTAVA, L. S., WERK, E. E., THRASHER, K., SHOLITON, L. J., KOZERA, R., NOLTEN, W., & KNOWLES, H. C. (1973). Plasma Cortisone Concentration as Measured by Radioimmunoassay. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-36-5-937
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.