Radioimmunoassay of Plasma Pregnenolone
The DOI matches its Crossref record.
Abstract
A radioimmunoassay for the measurement of plasma unconjugated pregnenolone (5Δ-P) is described. The 3-hemisuccinate of 5Δ-P was coupled to human serum albumin using carbodiimide. One adult ewe was immunized with 2 mg of this conjugate. The antiserum obtained after 7 months of immunization was used in the assay. One to two ml of plasma or serum, with 3H-5Δ-P added for recovery was extracted with ether and chromatographed on a microcolumn of celite. Incubation of the dried 5Δ-P fraction was carried out at 4 C in the presence of 3H-5Δ-P and diluted antiserum at 4 C in phosphate buffer with 0.1% gelatin. The mean recovery of 3H-5AΔ-P after extraction and chromatography was 62%. The sensitivity varied between 0.05 and 0.1 ng 5Δ-P. Recovery experiments of 5Δ-P added to plasma confirmed accuracy. Concentrations of 5Δ-P in plasma from men averaged 0.75 ± 0.55 (SD) ng/ml. Using single determinations during each phase of the menstrual cycle, premenopausal women had levels of 0.71 ± 0.45 (sd) and 1.38 ± 0.64 (sd) respectively during the follicular and luteal phases. However, when six premenopausal women were studied during a complete menstrual cycle, wide daily fluctuations in plasma 5Δ-P were observed with somewhat higher levels than during less frequent sampling. It is possible that the stress of daily venipuncture contributed to this increase in plasma 5Δ-P. Postmenopausal women showed a wide range of levels from 0.5 to 10.7 ng/ml with a mean of 2.7 ng/ml. The levels of 5Δ-P found by the present assay compared favorably with levels obtained under similar physiological conditions by other published methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DUNN, J. F., NISULA, B. C., & RODBARD, D. (1981) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-53-1-58 · Cited by 1,238
Artemenko, I. P., Zhao, D., Hales, D. B., Hales, K. H., & Jefcoate, C. R. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m107815200 · Cited by 217
Coghlan, V. M., & Vickery, L. E. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)55106-1 · Cited by 160
Control of sterol metabolism in rat adrenal mitochondria
Mason, J. I., Arthur, J. R., & Boyd, G. S. (1978) · Biochemical Journal · doi:10.1042/bj1741045 · Cited by 72
Arthur, J. R., Blair, H. A. F., Boyd, G. S., Mason, J. I., & Suckling, K. E. (1976) · Biochemical Journal · doi:10.1042/bj1580047 · Cited by 56
Metadata
- Authors
- ABRAHAM, G. E., BUSTER, J. E., KYLE, F. W., CORRALES, P. C., & TELLER, R. C.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1973-07
- Volume
- 37
- Issue
- 1
- Pages
- 40-45
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2109482230
- Cited by
- 78
- References
- 0
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radioimmunoassay of Plasma Pregnenolone. https://app.cochat.ai/papers/10.1210/jcem-37-1-40
- The paper
- ABRAHAM, G. E., BUSTER, J. E., KYLE, F. W., CORRALES, P. C., & TELLER, R. C. (1973). Radioimmunoassay of Plasma Pregnenolone. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-37-1-40
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.