CoChat

Intercomparison of Four Methods for Measuring Cortisol Production

ZUMOFF, BARNETT, FUKUSHIMA, D. K., HELLMAN, LEON · 1974 · The Journal of Clinical Endocrinology & Metabolism
Cited by 69

The DOI matches its Crossref record.

Abstract

Four methods of measuring the daily cortisol production rate were intercompared in 49 patients with production rates varying between 2 and 60 mg per day: a. “Urinary” production rate by isotope dilution; b. “Urinary” production rate by quantitating the excretion of endogenous THF + ATHF + THE and multiplying their sum by an empirically derived constant; c. Plasma production rate by multiplying the MCR by the 24-hr mean plasma cortisol concentration; d. Plasma production rate by summation of incremental secretion, calculated from the episodic secretory peaks defined by the 72 sample 24-hr study technique previously reportd from this laboratory. It was found that these four methods yield values whose relationships, on the average, are completely predictable: a. The two “urinary” production rates yield identical values; b. Plasma production rate by summation of incremental secretion very slightly underestimates plasma production rate by MCR, because of the small proportion (less than 19%) of the daily cortisol secretion that occurs between obvious secretory episodes; c. Plasma production rate by MCR is a constant fraction (75%) of the “urinary” production rate. The following conclusions were drawn: a. The predictable relationships observed make it possible to directly intercompare cortisol production rate data derived by any of the four methods, thereby greatly extending the amount of already published data that can be interpreted; b. The fact that the plasma production rate is a constant fraction of the “urinary” production rate appears to mean that some compound contributes to the formation or urinary cortisol metabolites without mixing with the plasma cortisol pool. Reasons are adduced for postulating that this compound is probably cortisone; c. The true adrenal secretion rate probably lies between a lower limit represented by the plasma production rate and an upper limit represented by the “urinary” production rate. The true secretion rate can therefore be measured with an error of less than 25%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem-38-2-169

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
ZUMOFF, B., FUKUSHIMA, D. K., & HELLMAN, L.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1974-02
Volume
38
Issue
2
Pages
169-175
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2012424288
Cited by
69
References
0
FWCI
0.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intercomparison of Four Methods for Measuring Cortisol Production. https://app.cochat.ai/papers/10.1210/jcem-38-2-169
The paper
ZUMOFF, B., FUKUSHIMA, D. K., & HELLMAN, L. (1974). Intercomparison of Four Methods for Measuring Cortisol Production. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-38-2-169

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.