CoChat

Characterization of the Optimal Stimulatory Effects of Graves’ Monoclonal and Serum Immunoglobulin G on Adenosine 3′,5′-Monophosphate Production in FRTL-5 Thyroid Cells: A Potential Clinical Assay

VITTI, PAOLO, ROTELLA, CARLO M., VALENTE, WILLIAM A., COHEN, JOSHUA, ALOJ, SALVATORE M., LACCETTI, PAOLO, AMBESI-IMPIOMBATO, FRANCESCO S., GROLLMAN, EVELYN F., PINCHERA, ALDO, TOCCAFONDI, ROBERTO, KOHN, LEONARD D. · 1983 · The Journal of Clinical Endocrinology & Metabolism
Cited by 160

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Immunoglobulin G (IgG) preparations derived from the sera of patients with hyperthyroidism due to Graves' disease (TSAb) as well as a monoclonal IgG derived from heterohybridoma fusions of Graves' lymphocytes augmented cAMP levels in a continuous strain of functioning rat thyroid cells (clone FRTL-5) in culture. Optimal stimulation was the same for both types of IgG preparations when measured after 2 h of incubation with 5 X 10(4) cells/well and using cells maintained in a nongrowth, TSH-deficient medium for 7 days. At low IgG concentrations, the stimulatory activities of both preparations exhibited a linear dependence on concentration and similar Ka values (approximately 4 X 10(-8) M) despite the fact that 65% of the Graves' serum IgG preparations had a significantly better ability to inhibit TSH binding to membrane preparations. The Ka value for TSH in the same assay was about 5 X 10(-12) M. Using this cell assay, 90% of a series of hyperthyroid Graves' IgG preparations exhibited stimulating activity, a value comparable to the frequency of positive results found by ourselves and others using human thyroid cell and slice systems. In contrast, only 10% of patients who were euthyroid 1 yr after antithyroid drug withdrawal (n = 21) exhibited stimulating activity, and no stimulating activity was detected in patients with nontoxic nodular goiter (n = 11), toxic adenoma (n = 5), or thyroid carcinoma (n = 6). The studies suggest that an optimized rat FRTL-5 thyroid cell system is a clinically useful and convenient alternative to human thyroid cell and slice systems for detecting TSAbs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem-57-4-782

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Metadata

Authors
VITTI, P., ROTELLA, C. M., VALENTE, W. A., COHEN, J., ALOJ, S. M., LACCETTI, P., AMBESI-IMPIOMBATO, F. S., GROLLMAN, E. F., PINCHERA, A., TOCCAFONDI, R., & KOHN, L. D.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1983-10
Volume
57
Issue
4
Pages
782-791
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2007878086
Cited by
160
References
19
FWCI
8.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.