The DOI matches its Crossref record.
A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*
Abstract
This report describes a microassay for 1,25-dihydroxyvitamin D [1,25-(OH)2D] in plasma which does not require high performance liquid chromatography. The assay involves rapid extraction and preliminary purification on a C-18 Sep-Pak cartridge, followed by final purification on a silica Sep-Pak using hexane-isopropanol. Quantitation of 1,25-(OH)2D is achieved using a nonequilibrium assay employing 1,25-(OH)2D receptor from calf thymus. The method is sensitive to 1.5 pg/tube, with B50 occurring at 9 pg/tube and a useful assay range of 1.5-40 pg/tube. The intra- and interassay coefficients of variation are 6.5% and 11.5%, respectively, and the method is linear over a wide range of sample dilutions. In addition, this assay measures both 1,25-(OH)2D2 and 1,25-(OH)2D3 with equal affinity. The importance of using an assay with equal affinity for 1,25-(OH)2D2 and 1,25-(OH)2D3 is demonstrated by the findings that 25-hydroxyvitamin D2 (250HD2) constituted 38.9% of the total 25-OHD found in clinical samples (12.6 +/- 0.7 ng/ml 25-OHD2 vs. 20.1 +/- 0.5 ng/ml 25-OHD3; n = 807). Results of this new assay have been compared to those of the assay of Horst et al. (21), which employs Sephadex LH-20 and high performance liquid chromatography sample purification. The correlation coefficient was r2 = 0.96, and the slope was 1.05. Using this new assay, plasma 1,25-(OH)2D concentrations were as follows: normal adults, 37.4 +/- 2.2 pg/ml (n = 22); chronic renal failure, 10.6 +/- 1.5 pg/ml (n = 7); anephrics, undetectable (n = 10); infant cord blood, 22.9 +/- 4.4 pg/ml (n = 7); and hyperparathyroidism, 68.9 +/- 5.0 pg/ml (n = 13). This assay should be particularly useful in pediatric or other studies in which sample size is limited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dietary Phosphorus Regulates Serum Fibroblast Growth Factor-23 Concentrations in Healthy Men
Antoniucci, D. M., Yamashita, T., & Portale, A. A. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0021 · Cited by 421
Krall, E. A., Sahyoun, N., Tannenbaum, S., Dallal, G. E., & Dawson-Hughes, B. (1989) · New England Journal of Medicine · doi:10.1056/nejm198912283212602 · Cited by 345
Seymour, J., & Gagel, R. (1993) · Blood · doi:10.1182/blood.v82.5.1383.1383 · Cited by 291
Smoking and bone loss among postmenopausal women
Krall, E. A., & Dawson-Hughes, B. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060404 · Cited by 256
Accelerated Bone Loss in Hypothyroid Patients Overtreated with L-Thyroxine
Stall, G. M., Harris, S., Sokoll, L. J., & Dawson-Hughes, B. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-4-265 · Cited by 203
Metadata
- Authors
- REINHARDT, T. A., HORST, R. L., ORF, J. W., & HOLLIS, B. W.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1984-01
- Volume
- 58
- Issue
- 1
- Pages
- 91-98
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2167999248
- Cited by
- 801
- References
- 0
- FWCI
- 37.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*. https://app.cochat.ai/papers/10.1210/jcem-58-1-91
- The paper
- REINHARDT, T. A., HORST, R. L., ORF, J. W., & HOLLIS, B. W. (1984). A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-58-1-91
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.