Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 801

The DOI matches its Crossref record.

A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*

REINHARDT, TIMOTHY A., HORST, RONALD L., ORF, JOHN W., HOLLIS, BRUCE W.·1984·The Journal of Clinical Endocrinology & Metabolism

Abstract

This report describes a microassay for 1,25-dihydroxyvitamin D [1,25-(OH)2D] in plasma which does not require high performance liquid chromatography. The assay involves rapid extraction and preliminary purification on a C-18 Sep-Pak cartridge, followed by final purification on a silica Sep-Pak using hexane-isopropanol. Quantitation of 1,25-(OH)2D is achieved using a nonequilibrium assay employing 1,25-(OH)2D receptor from calf thymus. The method is sensitive to 1.5 pg/tube, with B50 occurring at 9 pg/tube and a useful assay range of 1.5-40 pg/tube. The intra- and interassay coefficients of variation are 6.5% and 11.5%, respectively, and the method is linear over a wide range of sample dilutions. In addition, this assay measures both 1,25-(OH)2D2 and 1,25-(OH)2D3 with equal affinity. The importance of using an assay with equal affinity for 1,25-(OH)2D2 and 1,25-(OH)2D3 is demonstrated by the findings that 25-hydroxyvitamin D2 (250HD2) constituted 38.9% of the total 25-OHD found in clinical samples (12.6 +/- 0.7 ng/ml 25-OHD2 vs. 20.1 +/- 0.5 ng/ml 25-OHD3; n = 807). Results of this new assay have been compared to those of the assay of Horst et al. (21), which employs Sephadex LH-20 and high performance liquid chromatography sample purification. The correlation coefficient was r2 = 0.96, and the slope was 1.05. Using this new assay, plasma 1,25-(OH)2D concentrations were as follows: normal adults, 37.4 +/- 2.2 pg/ml (n = 22); chronic renal failure, 10.6 +/- 1.5 pg/ml (n = 7); anephrics, undetectable (n = 10); infant cord blood, 22.9 +/- 4.4 pg/ml (n = 7); and hyperparathyroidism, 68.9 +/- 5.0 pg/ml (n = 13). This assay should be particularly useful in pediatric or other studies in which sample size is limited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem-58-1-91

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 801

Metadata

Authors
REINHARDT, T. A., HORST, R. L., ORF, J. W., & HOLLIS, B. W.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1984-01
Volume
58
Issue
1
Pages
91-98
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2167999248
Cited by
801
References
0
FWCI
37.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*. https://app.cochat.ai/papers/10.1210/jcem-58-1-91
The paper
REINHARDT, T. A., HORST, R. L., ORF, J. W., & HOLLIS, B. W. (1984). A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-58-1-91

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.