Cited by 75Thyroid Disorders and TreatmentsClinical Laboratory Practices and Quality ControlThyroid Cancer Diagnosis and Treatment

Measurement of Thyrotropin in Clinical and Subclinical Hyperthyroidism Using a New Chemiluminescent Assay*

ROSS, DOUGLAS S., ARDISSON, LINDA J., MESKELL, MICHAEL J.·1989·The Journal of Clinical Endocrinology & Metabolism

Abstract

A new commercially available chemiluminescent TSH assay demonstrates an 8- to 10-fold increase in sensitivity over a sensitive immunoradiometric assay, allowing increased ability to distinguish partial from more complete thyrotroph suppression. Sera were analyzed from 145 patients who had TSH concentrations below 0.08 mU/L in the immunoradiometric assay. Most patients with overt hyperthyroidism had undetectable TSH concentrations in the chemiluminescent assay. Three groups of patients were identified, in which a large subgroup had undetectable values in the immunoradiometric assay and detectable values in the chemiluminescent assay (12 of 17 patients under treatment for hyperthyroidism who had recently normalized their serum thyroid hormone levels, 33 of 68 patients taking L-T4, and 4 of 8 patients with endogenous subclinical hyperthyroidism). In addition, several patients with undetectable basal and detectable TRH-stimulated TSH values in the immunoradiometric assay had detectable basal TSH values in the chemiluminescent assay. The utility of first generation TSH immunometric assays was their ability to distinguish hyperthyroidism from euthyroidism. The clinical utility of increasingly sensitive TSH assays will be to distinguish degrees of thyrotroph suppression in subclinical hyperthyroidism.

Integrity signals

Registry

Crossref · 10.1210/jcem-69-3-684

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
ROSS, D. S., ARDISSON, L. J., & MESKELL, M. J.
Affiliations
  • Massachusetts General Hospital (US)
  • Harvard University (US)
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1989-09
Volume
69
Issue
3
Pages
684-688
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2004324253
Cited by
75
References
0
Citations by year
2024: 1 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 2
FWCI
5.24
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (DK-01415)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Cancer Diagnosis and Treatment
Keywords
thyroid-stimulating hormone, TSH measurement, chemiluminescence immunoassay, subclinical hyperthyroidism, overt hyperthyroidism, immunoradiometric assay, levothyroxine, thyrotropin-releasing hormone stimulation, assay sensitivity
MeSH terms
Goiter, Humans, Hyperthyroidism, Luminescent Measurements, Radioimmunoassay, Thyroid Diseases, Thyrotropin, Thyroxine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review