CoChat

Steroid 21-Hydroxylase Autoantibodies: Measurements with a New Immunoprecipitation Assay1

Tanaka, Hideaki, Perez, Maria S., Powell, Michael, Sanders, Jane F., Sawicka, Joanna, Chen, Shu, Prentice, Louise, Asawa, Takayuki, Betterle, Corrado, Volpato, Marina, Smith, Bernard Rees, Furmaniak, Jadwiga · 1997 · The Journal of Clinical Endocrinology & Metabolism
Cited by 79

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Autoantibodies (Abs) to steroid 21-hydroxylase (21-OH) are a major component of adrenal cortex Abs and are characteristic of autoimmune Addison's disease. We have developed a new method for measuring Abs to 21-OH based on 125I-labeled recombinant human 21-OH produced in yeast. With this assay, 21-OH Abs were detected in 43 of 60 (72%) sera from patients with isolated Addison's disease, 11 of 12 (92%) autoimmune polyglandular syndrome type I sera, 27 of 27 (100%) autoimmune polyglandular syndrome type II sera, and 24 of 30 (80%) sera from patients who were positive for adrenal cortex antibodies by immunofluorescence but had no overt Addison's disease. 21-OH Abs were found by 125I assay in 4 of 150 (2.7%) sera from patients with insulin-dependent diabetes mellitus, 1 of 77 (1.3%) Graves' sera, 1 of 67 (1.5%) Hashimoto's sera, and 6 of 243 (2.5%) sera from healthy blood donors. 21-OH Abs were not detected in 9 sera from patients with Addison's disease due to tuberculosis, 32 sera from patients with noninsulin-dependent diabetes mellitus, 35 sera from patients with myasthenia gravis, or 17 sera from patients with premature ovarian failure. There was good agreement between the 125I-labeled 21-OH assay and an assay based on 35S-labeled 21-OH produced in an in vitro transcription/translation system (r = 0.86; n = 129; P < 0.001). In the case of sera from patients with Addison's disease, insulin-dependent diabetes mellitus, Graves' disease, and Hashimoto's disease and from healthy blood donors that were low positive in the 125I assay, neutralization studies with unlabeled 21-OH confirmed the presence of specific 21-OH Abs. Overall, the 21-OH Ab assay based on 125I-labeled 21-OH showed good sensitivity, precision, and disease group specificity. This, combined with a simple assay protocol and the convenience of 125I handling and counting, make it attractive for routine use. Further investigations with the new assay should allow wider assessment of the prevalence and pattern of inheritance of adrenal autoimmunity. In addition, studies of the effect of treatment or possible preventative measures on 21-OH Ab levels in individuals without overt adrenal failure may suggest ways of delaying the onset of autoimmune Addison's disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem.82.5.3929

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Tanaka, H., Perez, M. S., Powell, M., Sanders, J. F., Sawicka, J., Chen, S., Prentice, L., Asawa, T., Betterle, C., Volpato, M., Smith, B. R., & Furmaniak, J.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1997-05
Volume
82
Issue
5
Pages
1440-1446
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2148088361
Cited by
79
References
4
FWCI
2.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.