CoChat

Profiling Steroid Hormones in Amniotic Fluid of Midpregnancy by Routine Stable Isotope Dilution/Gas Chromatography-Mass Spectrometry: Reference Values and Concentrations in Fetuses at Risk for 21-Hydroxylase Deficiency1

Wudy, Stefan A., Dörr, Helmuth G., Solleder, Claudia, Djalali, Mahmoud, Homoki, János · 1999 · The Journal of Clinical Endocrinology & Metabolism
Cited by 80

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Using routine stable isotope dilution/gas chromatography-mass spectrometry, 17-hydroxyprogesterone, androstenedione, testosterone, dehydroepiandrosterone, androstanediol, and 5alpha-dihydrotestosterone have been profiled in amniotic fluid of midgestation in 77 normal fetuses and 38 untreated or dexamethasone-treated fetuses at risk for 21-hydroxylase deficiency. Dexamethasone was suspended 5-7 days before amniocentesis. In normal fetuses, amniotic fluid concentrations (median, range; nanograms per mL) of 17-hydroxyprogesterone did not reveal a sex difference (1.48, 0.21-4.96), whereas those of androstenedione were lower in females (0.53, 0.00-2.71) than in males (0.93, 0.29-1.98). Testosterone levels were higher in males (0.24, 0.00-0.50) than in females (0.00, 0.00-0.27). No sex difference was found for dehydroepiandrosterone (0.47, 0.19-1.77). Levels of androstanediol and 5alpha-dihydrotestosterone were below the detection limit of our method in most cases. Regarding prenatal diagnosis of 21-hydroxylase deficiency, 17-hydroxyprogesterone and androstenedione presented the diagnostically most valuable steroids and were of equal diagnostic potential. They permitted successful diagnosis in 36 of 37 fetuses at risk: 12 were untreated and unaffected, 13 were treated and unaffected, 4 were untreated and affected (3 salt wasters and 1 simple virilizer), and 8 were treated and affected (5 salt wasters and 3 simple virilizers). In the latter group, one simple virilizer revealed normal steroid concentrations. Isotope dilution/gas chromatography-mass spectrometry, providing the highest specificity in steroid analysis, is proposed for routine use in clinical steroid analysis whenever maximal reliability is requested. Our study provides the first mass spectrometric reference data on amniotic fluid steroid concentrations and underscores the high accuracy of prenatal hormonal diagnosis of 21-hydroxylase deficiency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem.84.8.5870

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 80

Metadata

Authors
Wudy, S. A., Dörr, H. G., Solleder, C., Djalali, M., & Homoki, J.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1999-08-01
Volume
84
Issue
8
Pages
2724-2728
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2023581732
Cited by
80
References
2
FWCI
0.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Profiling Steroid Hormones in Amniotic Fluid of Midpregnancy by Routine Stable Isotope Dilution/Gas Chromatography-Mass Spectrometry: Reference Values and Concentrations in Fetuses at Risk for 21-Hydroxylase Deficiency1. https://app.cochat.ai/papers/10.1210/jcem.84.8.5870
The paper
Wudy, S. A., Dörr, H. G., Solleder, C., Djalali, M., & Homoki, J. (1999). Profiling Steroid Hormones in Amniotic Fluid of Midpregnancy by Routine Stable Isotope Dilution/Gas Chromatography-Mass Spectrometry: Reference Values and Concentrations in Fetuses at Risk for 21-Hydroxylase Deficiency1. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem.84.8.5870

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.