The quality of diagnostic accuracy studies since the STARD statement: Has it improved?
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess whether the quality of reporting of diagnostic accuracy studies has improved since the publication of the Standards for the Reporting of Diagnostic Accuracy studies (STARD statement). METHODS: The quality of reporting of diagnostic accuracy studies published in 12 medical journals in 2000 (pre-STARD) and 2004 (post-STARD) was evaluated by two reviewers independently. For each article, the number of reported STARD items was counted (range 0 to 25). Differences in completeness of reporting between articles published in 2000 and 2004 were analyzed, using multilevel analyses. RESULTS: We included 124 articles published in 2000 and 141 articles published in 2004. Mean number of reported STARD items was 11.9 (range 3.5 to 19.5) in 2000 and 13.6 (range 4.0 to 21.0) in 2004, an increase of 1.81 items (95% CI: 0.61 to 3.01). Articles published in 2004 reported the following significantly more often: methods for calculating test reproducibility of the index test (16% vs 35%); distribution of the severity of disease and other diagnoses (23% vs 53%); estimates of variability of diagnostic accuracy between subgroups (39% vs 60%); and a flow diagram (2% vs 12%). CONCLUSIONS: The quality of reporting of diagnostic accuracy studies has improved slightly over time, without a more pronounced effect in journals that adopted the STARD statement. As there is still room for improvement, editors should mention the use of the STARD statement as a requirement in their guidelines for authors, and instruct reviewers to check the STARD items. Authors should include a flow diagram in their manuscript.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
The Revised CONSORT Statement for Reporting Randomized Trials: Explanation and Elaboration
Altman, D. G., Schulz, K. F., Moher, D., Egger, M., Davidoff, F., Elbourne, D., Gøtzsche, P. C., Lang, T., & for the CONSORT Group (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-8-200104170-00012 · Cited by 3,835 · cited 1×
“0) b) for the reference standard 6 (5) 9 (6) 1.”
Improving the Quality of Reporting of Randomized Controlled Trials: The CONSORT Statement
Begg, C. (1996) · JAMA · doi:10.1001/jama.1996.03540080059030 · Cited by 3,127
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Moher, D., Schulz, K. F., Altman, D. G., & for the CONSORT Group* (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-8-200104170-00011 · Cited by 1,426
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Self-citationMoher, D., Jones, A., Lepage, L., & for the CONSORT Group (2001) · JAMA · doi:10.1001/jama.285.15.1992 · Cited by 1,027
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Clinical Chemistry · doi:10.1373/49.1.1 · Cited by 862
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 1×
“where data were collected 35 (28) 30 (21) 0.”
Self-citationEpidemiology and reporting of randomised trials published in PubMed journals
Chan, A.-W., & Altman, D. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71879-1 · Cited by 474
Issues in the reporting of epidemiological studies: a survey of recent practice.
Pocock, S. J., Collier, T. J., Dandreo, K. J., de Stavola, B. L., Goldman, M. B., Kalish, L. A., Kasten, L. E., & McCormack, V. A. (2004) · BMJ · doi:10.1136/bmj.38250.571088.55 · Cited by 313
Publications on diagnostic test evaluation in family medicine journals
Devillé, W. L. J. M., Bezemer, P. D., & Bouter, L. M. (2000) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(99)00144-4 · Cited by 161
Self-citationQuality of Reporting of Diagnostic Accuracy Studies
Smidt, N., Rutjes, A. W. S., van der Windt, D. A. W. M., Ostelo, R. W. J. G., Reitsma, J. B., Bossuyt, P. M., Bouter, L. M., & de Vet, H. C. W. (2005) · Radiology · doi:10.1148/radiol.2352040507 · Cited by 138
Self-citationThe scandal of poor epidemiological research: ***
Elm, E. V., & Egger, M. (2004) · BMJ · doi:10.1136/bmj.329.7471.868 · Cited by 134 · cited 1×
“20 Any adverse events from performing the index tests or the reference standard 21 (17) 16 (11) 0.”
BackgroundReporting of measures of accuracy in systematic reviews of diagnostic literature
Honest, H., & Khan, K. S. (2002) · BMC Health Services Research · doi:10.1186/1472-6963-2-4 · Cited by 112
Stengel, D., Bauwens, K., Rademacher, G., Mutze, S., & Ekkernkamp, A. (2005) · Radiology · doi:10.1148/radiol.2361040791 · Cited by 75
Smidt, N., Rutjes, A. W., van der Windt, D. A., Ostelo, R. W., Bossuyt, P. M., Reitsma, J. B., Bouter, L. M., & de Vet, H. C. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-12 · Cited by 66
Self-citationThe quality of reporting of diagnostic accuracy studies published in ophthalmic journals
Siddiqui, M. A. R., Azuara-Blanco, A., & Burr, J. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.051862 · Cited by 44
Improving the flow of diagnostic information: The importance of STARD for authors and readers
Holloway, R. G. (2003) · Neurology · doi:10.1212/01.wnl.0000089443.41909.c7 · Cited by 9 · cited 1×
“13 Methods for calculating test reproducibility, if done a) for the index test 20 (16) 49 (35) 2.”
Method
Research works printed but not linked: 2
- 10.1373/49.1.7 · doi:10.1373/49.1.7 · Paper page
- Reeves BC. Evidence about evidence. Br J Ophthalmol 2005;89:253–254.
Cited by
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223
Guidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Reducing waste from incomplete or unusable reports of biomedical research
Glasziou, P., Altman, D. G., Bossuyt, P., Boutron, I., Clarke, M., Julious, S., Michie, S., Moher, D., & Wager, E. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62228-x · Cited by 1,319
Self-citationSystematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationA catalogue of reporting guidelines for health research
Simera, I., Moher, D., Hoey, J., Schulz, K. F., & Altman, D. G. (2010) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2009.02234.x · Cited by 1,047
Metadata
- Authors
- Smidt, N., Rutjes, A. W. S., van der Windt, D. A. W. M., Ostelo, R. W. J. G., Bossuyt, P. M., Reitsma, J. B., Bouter, L. M., & de Vet, H. C. W.
- Venue
- Neurology
- Published
- 2006-09-12
- Volume
- 67
- Issue
- 5
- Pages
- 792-797
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2052520914
- Cited by
- 235
- References
- 20
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Update notices
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.