Overdiagnosis of idiopathic intracranial hypertension
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To delineate the factors contributing to overdiagnosis of idiopathic intracranial hypertension (IIH) among patients seen in one neuro-ophthalmology service at a tertiary center. METHODS: We retrospectively reviewed new patients referred with a working diagnosis of IIH over 8 months. The Diagnosis Error Evaluation and Research taxonomy tool was applied to cases referred with a diagnosis of IIH and a discrepant final diagnosis. RESULTS: Of 1,249 patients, 165 (13.2%) were referred either with a preexisting diagnosis of IIH or to rule out IIH. Of the 86/165 patients (52.1%) with a preexisting diagnosis of IIH, 34/86 (39.5%) did not have IIH. The most common diagnostic error was inaccurate ophthalmoscopic examination in headache patients. Of 34 patients misdiagnosed as having IIH, 27 (27/34 [79.4%]; 27/86 [31.4%]) had at least one lumbar puncture, 29 (29/34 [85.3%]; 29/86 [33.7%]) had a brain MRI, and 8 (8/34 [23.5%]; 8/86 [9.3%]) had a magnetic resonance/CT venogram. Twenty-six had received medical treatment, 1 had a lumbar drain, and 4 were referred for surgery. In 8 patients (8/34 [23.5%]; 8/86 [9.3%]), an alternative diagnosis requiring further evaluation was identified. CONCLUSIONS: Diagnostic errors resulted in overdiagnosis of IIH in 39.5% of patients referred for presumed IIH, and prompted unnecessary tests, invasive procedures, and missed diagnoses. The most common errors were inaccurate ophthalmoscopic examination in headache patients and thinking biases, reinforcing the need for rapid access to specialists with experience in diagnosing optic nerve disorders. Indeed, the high prevalence of primary benign headaches and obesity in young women often leads to costly and invasive evaluations for presumed IIH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The International Classification of Headache Disorders, 3rd edition (beta version)
Headache Classification Committee of the International Headache Society (IHS) (2013) · Cephalalgia · doi:10.1177/0333102413485658 · Cited by 8,229
Prevalence of Childhood and Adult Obesity in the United States, 2011-2012
Ogden, C. L., Carroll, M. D., Kit, B. K., & Flegal, K. M. (2014) · JAMA · doi:10.1001/jama.2014.732 · Cited by 8,072
The Importance of Cognitive Errors in Diagnosis and Strategies to Minimize Them
Croskerry, P. (2003) · Academic Medicine · doi:10.1097/00001888-200308000-00003 · Cited by 1,675
Cited by
Idiopathic intracranial hypertension: consensus guidelines on management
Mollan, S. P., Davies, B., Silver, N. C., Shaw, S., Mallucci, C. L., Wakerley, B. R., Krishnan, A., Chavda, S. V., Ramalingam, S., Edwards, J., et al. (2018) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2017-317440 · Cited by 612
Incidence and causes of overdiagnosis of optic neuritis.
Stunkel, L., Kung, N. H., Wilson, B., McClelland, C. M., & Van Stavern, G. P. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2017.5470 · Cited by 117
Patient harm due to diagnostic error of neuro-ophthalmologic conditions.
Stunkel, L., Sharma, R. A., Mackay, D. D., Wilson, B., Van Stavern, G. P., Newman, N. J., & Biousse, V. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2021.03.008 · Cited by 54
Self-citationReferral patterns in neuro-ophthalmology
Stunkel, L., Mackay, D. D., Bruce, B. B., Newman, N. J., & Biousse, V. (2020) · Journal of Neuro-Ophthalmology · doi:10.1097/wno.0000000000000846 · Cited by 37
“A growing body of literature demonstrates alarmingly high rates of misdiagnosis of neuroophthalmologic conditions before evaluation by a neuroophthalmologist (5–12), and also sheds light on the costly and potentially harmful unnecessary studies and treatments that are frequently obtained before neuroophthalmology cons…”
BackgroundDiagnostic error and neuro-ophthalmology
Stunkel, L., Newman, N. J., & Biousse, V. (2019) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000635 · Cited by 29
Self-citationHamedani, A. G., De Lott, L. B., Deveney, T., & Moss, H. E. (2020) · Journal of Neuro-Ophthalmology · doi:10.1097/wno.0000000000000971 · Cited by 19
“As neuro-ophthalmic disorders are especially prone to diagnostic error (10,11), validation studies that confirm the accuracy of ICD-9 and ICD-10 codes are important for performing and interpreting the results of administrative claims studies in neuro-ophthalmology.”
Background
Metadata
- Authors
- Fisayo, A., Bruce, B. B., Newman, N. J., & Biousse, V.
- Venue
- Neurology
- Published
- 2016-01-26
- Volume
- 86
- Issue
- 4
- Pages
- 341-350
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2217122051
- Cited by
- 164
- References
- 3
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.