Removing high-frequency oscillations: A prospective multicenter study on seizure outcome
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the use of interictal high-frequency oscillations (HFOs) in epilepsy surgery for prediction of postsurgical seizure outcome in a prospective multicenter trial. METHODS: We hypothesized that a seizure-free outcome could be expected in patients in whom the surgical planning included the majority of HFO-generating brain tissue while a poor seizure outcome could be expected in patients in whom only a few such areas were planned to be resected. Fifty-two patients were included from 3 tertiary epilepsy centers during a 1-year period. Ripples (80-250 Hz) and fast ripples (250-500 Hz) were automatically detected during slow-wave sleep with chronic intracranial EEG in 2 centers and acute intraoperative electrocorticography in 1 patient. RESULTS: There was a correlation between the removal of HFO-generating regions and seizure-free outcome at the group level for all patients. No correlation was found, however, for the center-specific analysis, and an individual prognostication of seizure outcome was true in only 36 patients (67%). Moreover, some patients became seizure-free without removal of the majority of HFO-generating tissue. The investigation of influencing factors, including comparisons of visual and automatic analysis, using a threshold analysis for areas with high HFO activity, and excluding contacts bordering the resection, did not result in improved prognostication. CONCLUSIONS: On an individual patient level, a prediction of outcome was not possible in all patients. This may be due to the analysis techniques used. Alternatively, HFOs may be less specific for epileptic tissue than earlier studies have indicated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Presurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669
High‐frequency electroencephalographic oscillations correlate with outcome of epilepsy surgery
Jacobs, J., Zijlmans, M., Zelmann, R., Chatillon, C., Hall, J., Olivier, A., Dubeau, F., & Gotman, J. (2010) · Annals of Neurology · doi:10.1002/ana.21847 · Cited by 673 · cited 3×
“that more HFO-generating areas have to be removed than remain for a patient to be seizure-free.(9,14) There is, however, no clear evidence that this assumption is right, and it may be necessary to remove all areas generating epileptic HFOs.”
BackgroundResultSelf-citationJacobs, J., LeVan, P., Chander, R., Hall, J., Dubeau, F., & Gotman, J. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01656.x · Cited by 634
Self-citationHigh‐frequency oscillations: What is normal and what is not?
Engel Jr, J., Bragin, A., Staba, R., & Mody, I. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2008.01917.x · Cited by 516
Worrell, G. A., Gardner, A. B., Stead, S. M., Hu, S., Goerss, S., Cascino, G. J., Meyer, F. B., Marsh, R., & Litt, B. (2008) · Brain · doi:10.1093/brain/awn006 · Cited by 458 · cited 12×
“A solution to this problem is to use, as in retrospective studies, individual thresholds to determine the area of highest HFO activity within an individual patient.11,19 For instance, there is controversial evidence for the influence of electrode types and size of contacts on the measurable rates of HFOs.34,35 HFO cou…”
ResultInfluentialHigh-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
Self-citationHigh‐frequency oscillations: The state of clinical research
Frauscher, B., Bartolomei, F., Kobayashi, K., Cimbalnik, J., van ‘t Klooster, M. A., Rampp, S., Otsubo, H., Höller, Y., Wu, J. Y., Asano, E., et al. (2017) · Epilepsia · doi:10.1111/epi.13829 · Cited by 395 · cited 2×
“Even if interictal HFOs are thought to be better biomarkers for epileptic tissue than epileptic spikes, they have not been used in routine presurgical diagnostic workup for 2 main reasons: analysis methods are complicated, and the clinical evidence for using HFOs to tailor epilepsy surgery is too weak.(16) The present…”
BackgroundMethodSelf-citationHigh‐frequency Oscillations after Status Epilepticus: Epileptogenesis and Seizure Genesis
Bragin, A., Wilson, C. L., Almajano, J., Mody, I., & Engel, J. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.17004.x · Cited by 339 · cited 1×
“Studies in rodents with mesial temporal and posttraumatic epilepsy have shown that HFOs are closely linked to epileptogenicity.(43,44) HFOs occurred only in animals that developed chronic epilepsy in contrast to those that remained healthy after initial injury.”
BackgroundHigh frequency oscillations in intracranial EEGs mark epileptogenicity rather than lesion type
Jacobs, J., LeVan, P., Châtillon, C.-É., Olivier, A., Dubeau, F., & Gotman, J. (2009) · Brain · doi:10.1093/brain/awn351 · Cited by 336
Self-citationRemoving interictal fast ripples on electrocorticography linked with seizure freedom in children
Wu, J. Y., Sankar, R., Lerner, J. T., Matsumoto, J. H., Vinters, H. V., & Mathern, G. W. (2010) · Neurology · doi:10.1212/wnl.0b013e3181fc27d0 · Cited by 306
Self-citationCrépon, B., Navarro, V., Hasboun, D., Clemenceau, S., Martinerie, J., Baulac, M., Adam, C., & Le Van Quyen, M. (2010) · Brain · doi:10.1093/brain/awp277 · Cited by 286 · cited 1×
“In a subset of these cases, intracranial video-EEG monitoring is performed for several days with EEG electrodes placed subdurally as a grid or stereotactically with intracerebral probes.(3) Alternatively, acute intraoperative subdural EEG recordings (electrocorticography [ECoG]) are obtained during the surgery.”
BackgroundAkiyama, T., McCoy, B., Go, C. Y., Ochi, A., Elliott, I. M., Akiyama, M., Donner, E. J., Weiss, S. K., Snead, O. C., Rutka, J. T., et al. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03199.x · Cited by 271 · cited 2×
“A solution to this problem is to use, as in retrospective studies, individual thresholds to determine the area of highest HFO activity within an individual patient.(11,19) For instance, there is controversial evidence for the influence of electrode types and size of contacts on the measurable rates of HFOs.”
MethodHigh-frequency oscillations mirror disease activity in patients with epilepsy
Zijlmans, M., Jacobs, J., Zelmann, R., Dubeau, F., & Gotman, J. (2009) · Neurology · doi:10.1212/01.wnl.0000344402.20334.81 · Cited by 243 · cited 12×
“A solution to this problem is to use, as in retrospective studies, individual thresholds to determine the area of highest HFO activity within an individual patient.11,19 For instance, there is controversial evidence for the influence of electrode types and size of contacts on the measurable rates of HFOs.34,35 HFO cou…”
BackgroundInfluentialSelf-citationRipple classification helps to localize the seizure‐onset zone in neocortical epilepsy
Wang, S., Wang, I. Z., Bulacio, J. C., Mosher, J. C., Gonzalez‐Martinez, J., Alexopoulos, A. V., Najm, I. M., & So, N. K. (2013) · Epilepsia · doi:10.1111/j.1528-1167.2012.03721.x · Cited by 227
High‐frequency oscillations are not better biomarkers of epileptogenic tissues than spikes
Roehri, N., Pizzo, F., Lagarde, S., Lambert, I., Nica, A., McGonigal, A., Giusiano, B., Bartolomei, F., & Bénar, C. (2018) · Annals of Neurology · doi:10.1002/ana.25124 · Cited by 222 · cited 2×
“HFOs were not better in identifying seizure onset compared to spikes in individual patients, contrary to what had been found in group-level studies.(15) The current results may therefore be limited to our specific patient groups.”
BackgroundResultPathological and physiological high-frequency oscillations in focal human epilepsy
Matsumoto, A., Brinkmann, B. H., Matthew Stead, S., Matsumoto, J., Kucewicz, M. T., Marsh, W. R., Meyer, F., & Worrell, G. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00341.2013 · Cited by 217
High-frequency oscillations in epileptic brain
Bragin, A., Engel, J., & Staba, R. J. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e3283373ac8 · Cited by 188 · cited 1×
“High-frequency oscillations (HFOs) can be recorded with these different intracranial EEG (iEEG) methods and were proposed as new biological markers of epileptic tissue.(7) HFOs commonly occur in brain areas showing the first ictal EEG activity, the seizure onset zone (SOZ),(4,8) and the removal of HFO-generating tissu…”
BackgroundHaegelen, C., Perucca, P., Châtillon, C., Andrade‐Valença, L., Zelmann, R., Jacobs, J., Collins, D. L., Dubeau, F., Olivier, A., & Gotman, J. (2013) · Epilepsia · doi:10.1111/epi.12075 · Cited by 188 · cited 3×
“that more HFO-generating areas have to be removed than remain for a patient to be seizure-free.(9,14) There is, however, no clear evidence that this assumption is right, and it may be necessary to remove all areas generating epileptic HFOs.”
BackgroundResultSelf-citationHigh-frequency oscillations in epilepsy and surgical outcome. A meta-analysis
Höller, Y., Kutil, R., Klaffenböck, L., Thomschewski, A., Höller, P. M., Bathke, A. C., Jacobs, J., Taylor, A. C., Nardone, R., & Trinka, E. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00574 · Cited by 165 · cited 2×
“This evidence derives from several epilepsy centers and includes data from different patients, adults, and children, distinct types of epilepsy, mesiotemporal and neocortical, and different analysis techniques.(13) These studies were retrospective and included small patient samples.”
BackgroundResultSelf-citationHuman Intracranial High Frequency Oscillations (HFOs) Detected by Automatic Time-Frequency Analysis
Burnos, S., Hilfiker, P., Sürücü, O., Scholkmann, F., Krayenbühl, N., Grünwald, T., & Sarnthein, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094381 · Cited by 158 · cited 12×
“A solution to this problem is to use, as in retrospective studies, individual thresholds to determine the area of highest HFO activity within an individual patient.11,19 For instance, there is controversial evidence for the influence of electrode types and size of contacts on the measurable rates of HFOs.34,35 HFO cou…”
InfluentialResidual fast ripples in the intraoperative corticogram predict epilepsy surgery outcome
Klooster, M. A. V. ’., van Klink, N. E. C., Leijten, F. S. S., Zelmann, R., Gebbink, T. A., Gosselaar, P. H., Braun, K. P. J., Huiskamp, G. J. M., & Zijlmans, M. (2015) · Neurology · doi:10.1212/wnl.0000000000001727 · Cited by 153
Self-citationNagasawa, T., Juhász, C., Rothermel, R., Hoechstetter, K., Sood, S., & Asano, E. (2011) · Human Brain Mapping · doi:10.1002/hbm.21233 · Cited by 146 · cited 1×
“Recent studies suggest that physiologic HFOs are not limited to mesial temporal structures, as initially thought, but also occur over occipital and central regions.(25,26) These studies demonstrated that physiologic and epileptic HFOs have a large frequency overlap and cannot be separated by frequency alone.”
BackgroundKerber, K., Dümpelmann, M., Schelter, B. O., LeVan, P., Korinthenberg, R., Schulze‐Bonhage, A., & Jacobs, J. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.11.030 · Cited by 140 · cited 1×
“In a previous dataset from Freiburg, pattern analysis was necessary to obtain significant differences in HFO removal between patients with good and those with poor outcome.(40) The varying results and rather weak evidence in the meta-analysis suggest that patient inclusion had influenced the results of these studies.”
ResultSelf-citationImproving the identification of High Frequency Oscillations
Zelmann, R., Zijlmans, M., Jacobs, J., Châtillon, C.-E., & Gotman, J. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.05.029 · Cited by 138 · cited 15×
“κ Coefficients were used to evaluate the agreement between visual and automatic markings.(18)”
BackgroundMethodInfluentialSelf-citationA storm of fast (40–150 H z) oscillations during hypsarrhythmia in West syndrome
Kobayashi, K., Akiyama, T., Oka, M., Endoh, F., & Yoshinaga, H. (2014) · Annals of Neurology · doi:10.1002/ana.24299 · Cited by 128 · cited 12×
“A solution to this problem is to use, as in retrospective studies, individual thresholds to determine the area of highest HFO activity within an individual patient.11,19 For instance, there is controversial evidence for the influence of electrode types and size of contacts on the measurable rates of HFOs.34,35 HFO cou…”
BackgroundInfluentialModur, P. N., Zhang, S., & Vitaz, T. W. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03165.x · Cited by 121
Fujiwara, H., Greiner, H. M., Lee, K. H., Holland‐Bouley, K. D., Seo, J. H., Arthur, T. M., Mangano, F. T., Leach, J., & Rose, D. F. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03629.x · Cited by 121
Liu, S., Gürses, C., Sha, Z., Quach, M. M., Sencer, A., Bebek, N., Curry, D. J., Prabhu, S. S., Tummala, S., Henry, T. R., et al. (2018) · Brain · doi:10.1093/brain/awx374 · Cited by 119 · cited 1×
“In contrast to physiologic HFO, epileptic events might be more repetitive andmonomorphic and can be identified by searching for events that do not change their morphology.(31) Another method is analyzing the co-occurrence of HFOs with physiologic phenomena such as sleep slow waves or sleep spindles to identify physiol…”
BackgroundNonoda, Y., Miyakoshi, M., Ojeda, A., Makeig, S., Juhász, C., Sood, S., & Asano, E. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.03.022 · Cited by 112 · cited 1×
“Recent studies suggest that physiologic HFOs are not limited to mesial temporal structures, as initially thought, but also occur over occipital and central regions.(25,26) These studies demonstrated that physiologic and epileptic HFOs have a large frequency overlap and cannot be separated by frequency alone.”
BackgroundPhase-Amplitude Coupling Is Elevated in Deep Sleep and in the Onset Zone of Focal Epileptic Seizures
Amiri, M., Frauscher, B., & Gotman, J. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00387 · Cited by 108 · cited 1×
“Recent studies aimed to distinguish physiologic HFOs by using amplitude and frequency values.(28,30) In contrast to physiologic HFO, epileptic events might be more repetitive andmonomorphic and can be identified by searching for events that do not change their morphology.”
BackgroundSelf-citationPathologic electrographic changes after experimental traumatic brain injury
Bragin, A., Li, L., Almajano, J., Alvarado‐Rojas, C., Reid, A. Y., Staba, R. J., & Engel, J. (2016) · Epilepsia · doi:10.1111/epi.13359 · Cited by 107 · cited 1×
“Studies in rodents with mesial temporal and posttraumatic epilepsy have shown that HFOs are closely linked to epileptogenicity.(43,44) HFOs occurred only in animals that developed chronic epilepsy in contrast to those that remained healthy after initial injury.”
BackgroundHigh-frequency oscillations in idiopathic partial epilepsy of childhood
Kobayashi, K., Yoshinaga, H., Toda, Y., Inoue, T., Oka, M., & Ohtsuka, Y. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03169.x · Cited by 102 · cited 1×
“HFOs were found to be closely linked to the SOZ in a large variety of epilepsies associated with developmental malformations, hippocampal sclerosis, and genetic disorders.(16,45) HFOs not only are recorded interictally but strongly increase directly before or during seizures.”
Backgroundvan Klink, N. E. C., Klooster, M. A. V. ’., Zelmann, R., Leijten, F. S. S., Ferrier, C. H., Braun, K. P. J., van Rijen, P. C., van Putten, M. J. A. M., Huiskamp, G. J. M., & Zijlmans, M. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.03.004 · Cited by 98 · cited 3×
“However, studies on intraoperative ECoG introduced the analysis of postsurgically remaining FR as a measure to predict surgical outcome.(10) After surgery, residual HFOs could not be predicted by the presurgical HFO distribution, and some areas stopped showing HFOs postoperatively even if they were not resected or dis…”
BackgroundInfluentialSelf-citationWeiss, S. A., Orosz, I., Salamon, N., Moy, S., Wei, L., Klooster, M. A. V. ’., Knight, R. T., Harper, R. M., Bragin, A., Fried, I., et al. (2016) · Epilepsia · doi:10.1111/epi.13572 · Cited by 90
Epileptic high‐frequency oscillations in intraoperative electrocorticography: The effect of propofol
Zijlmans, M., Huiskamp, G. J. M., Cremer, O. L., Ferrier, C. H., van Huffelen, A. C., & Leijten, F. S. S. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03650.x · Cited by 78
The role of high-frequency oscillations in epilepsy surgery planning
Gloss, D. S., Nevitt, S. J., & Staba, R. J. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010235.pub3 · Cited by 57
Surgical treatment of independent bitemporal lobe epilepsy defined by invasive recordings
Boling, W., Aghakhani, Y., Andermann, F., Sziklas, V., & Olivier, A. (2008) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2008.155291 · Cited by 45 · cited 1×
“Noninvasive diagnostics such asMRI, neuropsychology, and EEG do not always lead to a definite localization of the seizure focus.(2) In a subset of these cases, intracranial video-EEG monitoring is performed for several days with EEG electrodes placed subdurally as a grid or stereotactically with intracerebral probes.”
MethodHussain, S. A., Mathern, G. W., Hung, P., Weng, J. K., Sankar, R., & Wu, J. Y. (2017) · Epilepsy Research · doi:10.1016/j.eplepsyres.2017.06.010 · Cited by 44 · cited 1×
“Prior data from 2 of our centers have shown very different results.(9,21,38) Two meta-analyses of the existing studies, however, have already suggested that the evidence of HFOs as a predictor of surgical outcome is rather weak.”
ResultSelf-citationClinical significance of ictal high frequency oscillations in medial temporal lobe epilepsy
Usui, N., Terada, K., Baba, K., et al. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.02.006 · Cited by 38 · cited 1×
“HFOs not only are recorded interictally but strongly increase directly before or during seizures.(46,47) A reduction of antiepileptic medication results in an increase of HFOs, and successful treatment can be measured as a reduction of HFOs.”
BackgroundInfluence of contact size on the detection of HFOs in human intracerebral EEG recordings
Châtillon, C.-É., Zelmann, R., Hall, J. A., Olivier, A., Dubeau, F., & Gotman, J. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.02.113 · Cited by 38 · cited 12×
“A solution to this problem is to use, as in retrospective studies, individual thresholds to determine the area of highest HFO activity within an individual patient.11,19 For instance, there is controversial evidence for the influence of electrode types and size of contacts on the measurable rates of HFOs.34,35 HFO cou…”
ResultInfluentialSelf-citationThe role of high-frequency oscillations in epilepsy surgery planning
Gloss, D. S., Nolan, S. J., & Staba, R. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010235.pub2 · Cited by 35 · cited 1×
“Two meta-analyses of the existing studies, however, have already suggested that the evidence of HFOs as a predictor of surgical outcome is rather weak.(13,39) A retrospective study from Montreal showed that small changes in the patient sample might alter the statistics in a way that HFO removal and surgical outcome we…”
ResultHussain, S. A., Mathern, G. W., Sankar, R., & Wu, J. Y. (2016) · Epilepsy Research · doi:10.1016/j.eplepsyres.2016.09.017 · Cited by 24 · cited 2×
“An association between the removal of HFO-generating tissue and surgical seizure outcome has been suggested by retrospective(13,20) and prospective single-center studies.(21) Evidence has suggested that HFO measures are independent of recording technique and patient population.”
ResultSelf-citationDifferentiation of spindle associated hippocampal HFOs based on a correlation analysis
Piza, D. L., Bruder, J. C., Jacobs, J., Schulze‐Bonhage, A., Stieglitz, T., & Dümpelmann, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591972 · Cited by 9 · cited 1×
“Applying one of these methods to our data in the future might improve prognostication.(8,32,33)”
MethodSelf-citation
Cited by
Changing concepts in presurgical assessment for epilepsy surgery
Zijlmans, M., Zweiphenning, W., & van Klink, N. (2019) · Nature Reviews Neurology · doi:10.1038/s41582-019-0224-y · Cited by 217
Genc, S., Pennisi, M., Yeni, Y., Yildirim, S., Gattuso, G., Altinoz, M. A., Taghizadehghalehjoughi, A., Bolat, I., Tsatsakis, A., Hacımüftüoğlu, A., et al. (2022) · Antioxidants · doi:10.3390/antiox11071225 · Cited by 33
Metadata
- Authors
- Jacobs, J., Wu, J. Y., Perucca, P., Zelmann, R., Mader, M., Dubeau, F., Mathern, G. W., Schulze-Bonhage, A., & Gotman, J.
- Venue
- Neurology
- Published
- 2018-09-11
- Volume
- 91
- Issue
- 11
- Pages
- e1040-e1052
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2885247192
- Cited by
- 199
- References
- 43
- FWCI
- 14.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.