Criteria for defining interictal epileptiform discharges in EEG: A clinical validation study
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To define and validate criteria for accurate identification of EEG interictal epileptiform discharges (IEDs) using (1) the 6 sensor space criteria proposed by the International Federation of Clinical Neurophysiology (IFCN) and (2) a novel source space method. Criteria yielding high specificity are needed because EEG over-reading is a common cause of epilepsy misdiagnosis. METHODS: Seven raters reviewed EEG sharp transients from 100 patients with and without epilepsy (diagnosed definitively by video-EEG recording of habitual events). Raters reviewed the transients, randomized, and classified them as epileptiform or nonepileptiform in 3 separate rounds: in 2, EEG was reviewed in sensor space (scoring the presence/absence of each IFCN criterion for each transient or classifying unrestricted by criteria [expert scoring]); in the other, review and classification were performed in source space. RESULTS: Cutoff values of 4 and 5 criteria in sensor space and analysis in source space provided high accuracy (91%, 88%, and 90%, respectively), similar to expert scoring (92%). Two methods had specificity exceeding the desired threshold of 95%: using 5 IFCN criteria as cutoff and analysis in source space (both 95.65%); the sensitivity of these methods was 81.48% and 85.19%, respectively. CONCLUSIONS: The presence of 5 IFCN criteria in sensor space and analysis in source space are optimal for clinical implementation. By extracting these objective features, diagnostic accuracy similar to expert scorings is achieved. CLASSIFICATION OF EVIDENCE: This study provides Class III evidence that IFCN criteria in sensor space and analysis in source space have high specificity (>95%) and sensitivity (81%-85%) for identification of IEDs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879 · cited 1×
“Statistical analysis Based on the sensitivities and specificities obtained at cutoff values of 2–6 IFCN criteria in sensor space, we calculated the estimated receiver operating characteristic (ROC) curve.(30) We calculated 95% confidence intervals for sensitivity, specificity, and accuracy using the Wilson method,(31)…”
MethodNote on the Sampling Error of the Difference Between Correlated Proportions or Percentages
McNemar, Q. (1947) · Psychometrika · doi:10.1007/bf02295996 · Cited by 4,754 · cited 1×
“We calculated 95% confidence intervals for sensitivity, specificity, and accuracy using the Wilson method,(31) and we compared them between the IED identification methods using the McNemar test based on the true positive, the true negative, and both.(32)”
MethodProbable Inference, the Law of Succession, and Statistical Inference
Wilson, E. B. (1927) · Journal of the American Statistical Association · doi:10.1080/01621459.1927.10502953 · Cited by 4,476
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Epilepsy: A Comprehensive Textbook
(2008) · JAMA · doi:10.1001/jama.300.4.443-a · Cited by 2,341
Computing inter‐rater reliability and its variance in the presence of high agreement
Gwet, K. L. (2008) · British Journal of Mathematical and Statistical Psychology · doi:10.1348/000711006x126600 · Cited by 2,167
Epilepsy: A Comprehensive Textbook
Vaughn, B. (1998) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199805000-00039 · Cited by 1,390
Kane, N., Acharya, J., Beniczky, S., Caboclo, L., Finnigan, S., Kaplan, P. W., Shibasaki, H., Pressler, R., & van Putten, M. J. A. M. (2017) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2017.07.002 · Cited by 517 · cited 9×
“It has been suggested that 4 IFCN criteria should be fulfilled to qualify a transient as an IED.23 Although the cutoff value of 4 criteria had high accuracy, the specificity was only 85%, which is below the threshold of 95% expected for clinical implementation.”
BackgroundSelf-citationThe standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489
Self-citationSample size calculation should be performed for design accuracy in diagnostic test studies
Flahault, A., Cadilhac, M., & Thomas, G. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2004.12.009 · Cited by 468
Effectiveness of Multiple EEGs in Supporting the Diagnosis of Epilepsy: An Operational Curve
Salinsky, M., Kanter, R., & Dasheiff, R. M. (1987) · Epilepsia · doi:10.1111/j.1528-1157.1987.tb03652.x · Cited by 416 · cited 2×
“Repeated routine recordings and long-term video-EEG recordings increase the sensitivity of EEG for IEDs to 80%–90%.(1,4,39)”
BackgroundInterictal EEG and the Diagnosis of Epilepsy
Pillai, J., & Sperling, M. R. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00654.x · Cited by 318
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314 · cited 3×
“Repeated routine recordings and long-term video-EEG recordings increase the sensitivity of EEG for IEDs to 80%–90%.(1,4,39)”
BackgroundSelf-citationOverintepretation of EEGs and Misdiagnosis of Epilepsy
Benbadis, S. R., & Tatum, W. O. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200302000-00005 · Cited by 257 · cited 6×
“Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology. e2139 Visual analysis is still the gold standard in clinical EEG.1 However, most recordings are interpreted by neurologists without expert certification.2 Interictal epileptiform discharges (IEDs) are typically found in patients w…”
BackgroundInfluentialNoachtar, S., Binnie, C. D., Ebersole, J., Mauguı̀ere, F., Sakamoto, A. C., & Westmoreland, B. (1999) · PubMed · Cited by 254
Electroencephalogram epileptiform abnormalities in candidates for aircrew training
Gregory, R. P., Oates, T., & Merry, R. T. G. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90069-8 · Cited by 236
Uldall, P. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2004.064477 · Cited by 232
Scherg, M., Ille, N., Bornfleth, H., & Berg, P. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00001 · Cited by 208 · cited 2×
“Besides identification of IEDs, source space montages also help in localization, because they show the brain regions generating the discharges (figure 2), and aid in the separation of sublobar activities, for example, involving different parts of the temporal lobe, as documented previously.(24,25) Thus, interpreting E…”
BackgroundSelf-citationErrors in EEG Interpretation and Misdiagnosis of Epilepsy
Benbadis, S. R., & Lin, K. (2008) · European Neurology · doi:10.1159/000115641 · Cited by 178 · cited 7×
“Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology. e2139 Visual analysis is still the gold standard in clinical EEG.1 However, most recordings are interpreted by neurologists without expert certification.2 Interictal epileptiform discharges (IEDs) are typically found in patients w…”
BackgroundInfluentialChadwick, D. (2002) · BMJ · doi:10.1136/bmj.324.7336.495 · Cited by 158
Video‐EEG Monitoring in the Elderly: A Review of 94 Patients
McBride, A. E., Shih, T., & Hirsch, L. J. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.24401.x · Cited by 154
DOES THE INTERICTAL EEG HAVE A ROLE IN THE DIAGNOSIS OF EPILEPSY?
Goodin, D. S., & Aminoff, M. J. (1984) · The Lancet · doi:10.1016/s0140-6736(84)92281-5 · Cited by 149 · cited 1×
“The sensitivity of single, routine EEG recording is relatively low (32%–59%).(4,38,39) However, our data set was derived from LTM.”
Avoiding the costs of unrecognized psychological nonepileptic seizures
LaFrance, W. C., & Benbadis, S. R. (2006) · Neurology · doi:10.1212/01.wnl.0000224953.94807.be · Cited by 140
Benbadis, S. R. (2007) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2007.05.013 · Cited by 126
Avoiding the Pitfalls of EEG Interpretation in Childhood Epilepsy
Mizrahi, E. M. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb06021.x · Cited by 103
Normal Adult EEG and Patterns of Uncertain Significance
Tatum, W. O., Husain, A. M., Benbadis, S. R., & Kaplan, P. W. (2006) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000220110.92126.a6 · Cited by 100
A Practical Guide for Routine EEG Studies in Epilepsy
Engel, J. (1984) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198404000-00001 · Cited by 91 · cited 2×
“The body of knowledge is passed down by word of mouth from teacher to student, and EEG training is like an extensive process of probabilistic classification learning, where teachers provide reinforcement for the visually identified patterns.(5)”
BackgroundThe diagnostic value of initial video-EEG monitoring in children—Review of 1000 cases
Asano, E., Pawlak, C., Shah, A. K., Shah, J., Luat, A. F., Ahn‐Ewing, J., & Chugani, H. T. (2005) · Epilepsy Research · doi:10.1016/j.eplepsyres.2005.07.012 · Cited by 87
A bootstrap method for comparing correlated kappa coefficients
Vanbelle, S., & Albert, A. (2008) · Journal of Statistical Computation and Simulation · doi:10.1080/00949650701410249 · Cited by 74 · cited 1×
“We compared IRAs of the IED identification methods using bootstrap.(34) The analyses were performed using Stata version 15.”
MethodSignificance of Epileptiform Discharges in Patients without Epilepsy in the Community
Sam, M. C., & So, E. L. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.17101.x · Cited by 67 · cited 1×
“A much higher rate of 12% was found in a patient population where most patients had progressive neurologic disorders (known to have a higher rate of IEDs) but no history of seizure.(37) All our patients had a history of paroxysmal episodes, but none of our patients without epilepsy had progressive neurologic disorder.”
BackgroundPreventing misdiagnosis of epilepsy
Ferrie, C. D. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088906 · Cited by 65 · cited 1×
“Misdiagnosis has multiple detrimental consequences for patients.(12,13)”
Taking the EEG Back Into the Brain: The Power of Multiple Discrete Sources
Scherg, M., Berg, P., Nakasato, N., & Beniczky, S. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00855 · Cited by 64 · cited 3×
“Thus, interpreting EEG in source space may be more intuitive and easier to explain to young trainees.(25)”
BackgroundSelf-citationCharacteristics of EEG Interpreters Associated With Higher Interrater Agreement
Halford, J. J., Arain, A. M., Kalamangalam, G. P., LaRoche, S. M., Leonardo, B., Basha, M. M., Azar, N. J., Kutluay, E., Martz, G. U., Wolf, B. J., et al. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000344 · Cited by 56 · cited 1×
“Previous studies suggested that the optimal size for a group of experts scoring IEDs in EEG was between 6 and 10.(29) Raters independently evaluated the EEG samples in 3 different rounds (more than 1 month apart), in sensor space and in source space, the samples presented in different randomized order in each round.”
BackgroundFast evaluation of interictal spikes in long‐term EEG by hyper‐clustering
Scherg, M., Ille, N., Weckesser, D., Ebert, A., Ostendorf, A., Boppel, T., Schubert‐Bast, S., Larsson, P. G., Henning, O. J., & Bast, T. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03503.x · Cited by 54 · cited 2×
“By grouping similar types of spikes into clusters, the software tools can significantly reduce the time burden for reviewing the detected spikes.(40)”
MethodSelf-citation
Cited by
Automated Interpretation of Clinical Electroencephalograms Using Artificial Intelligence
Tveit, J., Aurlien, H., Plis, S., Calhoun, V. D., Tatum, W. O., Schomer, D. L., Arntsen, V., Cox, F., Fahoum, F., Gallentine, W. B., et al. (2023) · JAMA Neurology · doi:10.1001/jamaneurol.2023.1645 · Cited by 242
Self-citation
Metadata
- Authors
- Kural, M. A., Duez, L., Sejer Hansen, V., Larsson, P. G., Rampp, S., Schulz, R., Tankisi, H., Wennberg, R., Bibby, B. M., Scherg, M., & Beniczky, S.
- Venue
- Neurology
- Published
- 2020-05-19
- Volume
- 94
- Issue
- 20
- Pages
- e2139-e2147
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W3020080361
- Cited by
- 215
- References
- 36
- FWCI
- 14.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.