OBJECTIVE: The diagnosis of psychogenic nonepileptic seizures (PNES) can be challenging. In the absence of a gold standard to verify the reliability of the diagnosis by EEG-video, we sought to assess the interrater reliability of the diagnosis using EEG-video recordings. METHODS: Patient samples consisted of 22 unselected consecutive patients who underwent EEG-video monitoring and had at least an episode recorded. Other test results and histories were not provided because the goal was to assess the reliability of the EEG-video. Data were sent to 22 reviewers, who were board-certified neurologists and practicing epileptologists at epilepsy centers. Choices were 1) PNES, 2) epilepsy, and 3) nonepileptic but not psychogenic ("physiologic") events. Interrater agreement was measured using a kappa coefficient for each diagnostic category. We used generalized kappa coefficients, which measure the overall level of between-method agreement beyond that which can be ascribed to chance. We also report category-specific kappa values. RESULTS: For the diagnosis of PNES, there was moderate agreement (kappa = 0.57, 95% confidence interval [CI] 0.39-0.76). For the diagnosis of epilepsy, there was substantial agreement (kappa = 0.69, 95% CI 0.51-0.86). For physiologic nonepileptic episodes, the agreement was low (kappa = 0.09, 95% CI 0.02-0.27). The overall kappa statistic across all 3 diagnostic categories was moderate at 0.56 (95% CI 0.41-0.73). CONCLUSIONS: Interrater reliability for the diagnosis of psychogenic nonepileptic seizures by EEG-video monitoring was only moderate. Although this may be related to limitations of the study (diagnosis based on EEG-video alone, artificial nature of the forced choice paradigm, single episode), it highlights the difficulties and subjective components inherent to this diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.0b013e3181b78425

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 165

Metadata

Authors
Benbadis, S. R., LaFrance, W. C., Papandonatos, G. D., Korabathina, K., Lin, K., & Kraemer, H. C.
Venue
Neurology
Published
2009-09-15
Volume
73
Issue
11
Pages
843-846
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W1984207165
Cited by
165
References
1
FWCI
6.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interrater reliability of EEG-video monitoring. https://app.cochat.ai/papers/10.1212/wnl.0b013e3181b78425
The paper
Benbadis, S. R., LaFrance, W. C., Papandonatos, G. D., Korabathina, K., Lin, K., & Kraemer, H. C. (2009). Interrater reliability of EEG-video monitoring. Neurology. https://doi.org/10.1212/wnl.0b013e3181b78425

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.