Evidence-based guideline update: Intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology and the American Clinical Neurophysiology Society
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate whether spinal cord intraoperative monitoring (IOM) with somatosensory and transcranial electrical motor evoked potentials (EPs) predicts adverse surgical outcomes. METHODS: A panel of experts reviewed the results of a comprehensive literature search and identified published studies relevant to the clinical question. These studies were classified according to the evidence-based methodology of the American Academy of Neurology. Objective outcomes of postoperative onset of paraparesis, paraplegia, and quadriplegia were used because no randomized or masked studies were available. RESULTS AND RECOMMENDATIONS: Four Class I and 8 Class II studies met inclusion criteria for analysis. The 4 Class I studies and 7 of the 8 Class II studies reached significance in showing that paraparesis, paraplegia, and quadriplegia occurred in the IOM patients with EP changes compared with the IOM group without EP changes. All studies were consistent in showing all occurrences of paraparesis, paraplegia, and quadriplegia in the IOM patients with EP changes, with no occurrences of paraparesis, paraplegia, and quadriplegia in patients without EP changes. In the Class I studies, 16%-40% of the IOM patients with EP changes developed postoperative-onset paraparesis, paraplegia, or quadriplegia. IOM is established as effective to predict an increased risk of the adverse outcomes of paraparesis, paraplegia, and quadriplegia in spinal surgery (4 Class I and 7 Class II studies). Surgeons and other members of the operating team should be alerted to the increased risk of severe adverse neurologic outcomes in patients with important IOM changes (Level A).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, G. C. S., & Pell, J. P. (2003) · BMJ · doi:10.1136/bmj.327.7429.1459 · Cited by 1,157
Sala, F., Palandri, G., Basso, E., Lanteri, P., Deletis, V., Faccioli, F., & Bricolo, A. (2006) · Neurosurgery · doi:10.1227/01.neu.0000215948.97195.58 · Cited by 452
Fehlings, M. G., Brodke, D. S., Norvell, D. C., & Dettori, J. R. (2010) · Spine · doi:10.1097/brs.0b013e3181d8338e · Cited by 312
Handbook of clinical neurophysiology
Daube, J. R., & Mauguìere, F. (2003) · Elsevier eBooks · Cited by 219
Ethics and evidence based medicine
Kerridge, I., Lowe, M., & Henry, D. (1998) · BMJ · doi:10.1136/bmj.316.7138.1151 · Cited by 203
Assessment of spinal cord integrity during thoracoabdominal aortic aneurysm repair
Jacobs, M. J. H. M., Elenbaas, T. W. O., Schurink, G. W. H., Mess, W. H., & Mochtar, B. (2002) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)04154-1 · Cited by 123
Somatosensory- and motor-evoked potential monitoring during spine and spinal cord surgery
Costa, P., Bruno, A., Bonzanino, M., Massaro, F., Caruso, L., Vincenzo, I., Ciaramitaro, P., & Montalenti, E. (2006) · Spinal Cord · doi:10.1038/sj.sc.3101934 · Cited by 108
Additional patient outcomes and pathways in evaluations of testing
Bossuyt, P. M. M., & McCaffery, K. (2009) · Medical Decision Making · doi:10.1177/0272989x09347013 · Cited by 97
Sutter, M. A., Eggspuehler, A., Grob, D., Jeszenszky, D. J., Benini, A., Porchet, F., Mueller, A., & Dvořák, J. (2007) · European Spine Journal · doi:10.1007/s00586-007-0422-y · Cited by 94
Intraoperative Neurophysiologic Monitoring
Møller, A. R. (2001) · The Internet Journal of Neuromonitoring · doi:10.5580/18b0 · Cited by 78
Effects of compression and ischemia on spinal cord evoked potentials
Bennett, M. H. (1983) · Experimental Neurology · doi:10.1016/0014-4886(83)90303-5 · Cited by 64
Practice guidelines for the supervising professional: intraoperative neurophysiological monitoring
Skinner, S. A., COHEN, B. A., Morledge, D. E., McAuliffe, J. J., Hastings, J. D., Yingling, C. D., & McCaffrey, M. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9496-8 · Cited by 63
Skinner, S. A., Transfeldt, E. E., Mehbod, A. A., Mullan, J. C., & Perra, J. H. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.11.030 · Cited by 47
Metadata
- Authors
- Nuwer, M. R., Emerson, R. G., Galloway, G., Legatt, A. D., Lopez, J., Minahan, R., Yamada, T., Goodin, D. S., Armon, C., Chaudhry, V., Gronseth, G. S., & Harden, C. L.
- Venue
- Neurology
- Published
- 2012-02-21
- Volume
- 78
- Issue
- 8
- Pages
- 585-589
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2167832240
- Cited by
- 192
- References
- 13
- FWCI
- 15.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.