The DOI matches its Crossref record.
Speech localization using repetitive transcranial magnetic stimulation
Abstract
To evaluate whether repetitive transcranial magnetic stimulation (RTMS) may be used for speech localization, we compared the results from RTMS with the intracarotid amobarbital test (IAT) in 21 patients undergoing surgical treatment (amygdalohippocampectomy or anterior temporal lobe resection) for medically intractable partial epilepsy. None of the patients had aphasia. We stimulated the temporal and frontal cortex on each side at a frequency of 30 Hz for 1 second and increased the intensity until speech was inhibited. A list of words and forward and backward counting were used to test speech function. The IAT was performed on the hemisphere of proposed surgery by unilateral injection and simultaneous regional cerebral blood flow (rCBF) recordings. In one patient, there was doubt about hemisphere dominance and a second bilateral IAT was performed. Fifteen patients had left-sided speech dominance; one, left-sided dominance and a moderate right-sided speech inhibition; two, right-sided speech dominance; and one, bilateral speech representations (bilateral injection at the IAT) with both techniques. One patient showed bilateral with right-sided speech dominance by RTMS and showed right-sided speech inhibition with right-sided injection only at the IAT procedure. One patient differed from the rest, showing bilateral representations with right-sided speech dominance with RTMS and left-sided speech inhibition by IAT with left-sided injection only. The concordance was 95%. None of the patients had seizures provoked by the procedure. We conclude that speech localization with RTMS shows a high concordance with the results from the IAT and may be useful in addition to traditional techniques in speech localization.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wassermann, E. M. (1998) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(97)00096-8 · Cited by 2,293
Determination of language dominance using functional MRI: A comparison with the Wada test
Binder, J. R., Swanson, S. J., Hammeke, T. A., Morris, G. L., Mueller, W. M., Fischer, M., Benbadis, S., Frost, J. A., Rao, S. M., & Haughton, V. M. (1996) · Neurology · doi:10.1212/wnl.46.4.978 · Cited by 878
Devlin, J. T., Matthews, P. M., & Rushworth, M. F. S. (2003) · Journal of Cognitive Neuroscience · doi:10.1162/089892903321107837 · Cited by 576
Language lateralization in healthy right-handers
Knecht, S., Deppe, M., Dräger, B., Bobe, L., Lohmann, H., Ringelstein, E.-B., & Henningsen, H. (2000) · Brain · doi:10.1093/brain/123.1.74 · Cited by 538
Transcranial Magnetic Stimulation: Applications in Neuropsychiatry
George, M. S., Lisanby, S. H., & Sackeim, H. A. (1999) · Archives of General Psychiatry · doi:10.1001/archpsyc.56.4.300 · Cited by 496
Metadata
- Authors
- Jennum, P., Friberg, L., Fuglsang-Frederiksen, A., & Dam, M.
- Venue
- Neurology
- Published
- 1994-02
- Volume
- 44
- Issue
- 2
- Pages
- 269-269
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2027296412
- Cited by
- 178
- References
- 0
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Speech localization using repetitive transcranial magnetic stimulation. https://app.cochat.ai/papers/10.1212/wnl.44.2.269
- The paper
- Jennum, P., Friberg, L., Fuglsang-Frederiksen, A., & Dam, M. (1994). Speech localization using repetitive transcranial magnetic stimulation. Neurology. https://doi.org/10.1212/wnl.44.2.269
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.