Choosing the best needle for diagnostic lumbar puncture
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new generation of Atraumatic (blunt tipped) needles now exists in addition to the traditional Quincke (cutting tip) needles for LP. We wished to identify the optimal size and type of needle that should be used for this technique. Requirements include rapid and accurate transduction of CSF pressure and adequate flow rate for CSF collection purposes while minimizing headache and other neurologic sequelae. Different types of available Atraumatic and Quincke needles were tested in two models that simulated normal and raised CSF pressures. The flow rates and the time required for an accurate transduction of CSF pressure onto a standard spinal manometer through each needle type was measured. Overall, Atraumatic-tipped needles compared favorably with similarly sized Quincke needles tested. The 20-gauge needles displayed suitable flow and pressure transduction characteristics. Some of the 22-gauge Atraumatic needles rapidly measured CSF pressure, but their flow rates were only suitable for small volume CSF collection. There is extensive literature to support that neurologic sequelae are reduced using Atraumatic needles. Diagnostic LP can be easily and accurately performed by using a large Atraumatic needle with the potential for considerable reduction in post-LP headache and related neurologic sequelae.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment [RETIRED]: Magnetoencephalography (MEG)
(1992) · Neurology · doi:10.1212/wnl.42.1.1 · Cited by 232
Cited by
Post-dural puncture headache: pathogenesis, prevention and treatment
Turnbull, D. K., & Shepherd, D. B. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg231 · Cited by 851
A consensus protocol for the standardization of cerebrospinal fluid collection and biobanking
Teunissen, C. E., Petzold, A., Bennett, J. L., Berven, F. S., Brundin, L., Comabella, M., Franciotta, D., Frederiksen, J. L., Fleming, J. O., Furlan, R., et al. (2009) · Neurology · doi:10.1212/wnl.0b013e3181c47cc2 · Cited by 845
Consensus guidelines for lumbar puncture in patients with neurological diseases
Engelborghs, S., Niemantsverdriet, E., Struyfs, H., Blennow, K., Brouns, R., Comabella, M., Dujmovic, I., van der Flier, W., Frölich, L., Galimberti, D., et al. (2017) · Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring · doi:10.1016/j.dadm.2017.04.007 · Cited by 355
Ellis, R. J., Hsia, K., Spector, S. A., Nelson, J. A., Heaton, R. K., Wallace, M. R., Abramson, I., Atkinson, J. H., Grant, I., & McCutchan, J. A. (1997) · Annals of Neurology · doi:10.1002/ana.410420503 · Cited by 321
Evans, R. W., Armon, C., Frohman, E. M., & Goodin, D. S. (2000) · Neurology · doi:10.1212/wnl.55.7.909 · Cited by 296
Metadata
- Authors
- Carson, D., & Serpell, M.
- Venue
- Neurology
- Published
- 1996-07
- Volume
- 47
- Issue
- 1
- Pages
- 33-37
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2042970239
- Cited by
- 114
- References
- 1
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Choosing the best needle for diagnostic lumbar puncture. https://app.cochat.ai/papers/10.1212/wnl.47.1.33
- The paper
- Carson, D., & Serpell, M. (1996). Choosing the best needle for diagnostic lumbar puncture. Neurology. https://doi.org/10.1212/wnl.47.1.33
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.