The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Effects of intravenous immunoglobulin on muscle weakness and calcium-channel autoantibodies in the Lambert-Eaton myasthenic syndrome
Abstract
Intravenous immunoglobulin improves many antibody-mediated autoimmune disorders, but its mode of action is unknown. We investigated its effects on muscle strength and on the serum titer of the calcium-channel autoantibodies that are likely to be pathogenic in the Lambert-Eaton myasthenic syndrome (LEMS). In a randomized, double-blind, placebo-controlled crossover trial, serial indices of limb, respiratory, and bulbar muscle strength and the serum titer of calcium-channel antibodies in nine patients were compared over an 8-week period, using the area-under-the-curve approach, following infusion on two consecutive days of immunoglobulin at 1 g/kg body weight/day (total dose 2.0 g/kg body weight) or placebo (equivalent volume of 0.3% albumin). Calcium-channel antibodies were measured by radioimmunoassay using 125I-omega-conotoxin MVIIC. Direct anti-idiotypic actions of immunoglobulin were tested in this assay. Immunoglobulin infusion was followed by significant improvements in the three strength measures (p = 0.017 to 0.038) associated with a significant decline in serum calcium-channel antibody titers (p = 0.028). Improvement peaked at 2 to 4 weeks and was declining by 8 weeks. Mean serum titers were unchanged at 1 week, however, and direct anti-idiotypic neutralization by immunoglobulin was not demonstrable in vitro. We conclude that immunoglobulin causes a short-term improvement in muscle strength in LEMS that probably results from the induced reduction in calcium-channel autoantibodies. The reduction is not due to a direct neutralizing action of the immunoglobulin, but a delayed anti-idiotypic action cannot be excluded. Improvement following intravenous immunoglobulin in other autoantibody-mediated disorders may similarly be associated with decline in levels of pathogenic autoantibodies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Lewy body variant of Alzheimer's disease: A clinical and pathologic entity
Hansen, L., Salmon, D., Galasko, D., Masliah, E., Katzman, R., DeTeresa, R., Thal, L., Pay, M. M., Hofstetter, R., Klauber, M., et al. (1990) · Neurology · doi:10.1212/wnl.40.1.1 · Cited by 1,068
Assessment [RETIRED]: Magnetoencephalography (MEG)
(1992) · Neurology · doi:10.1212/wnl.42.1.1 · Cited by 232
Cited by
Paraneoplastic Syndromes: An Approach to Diagnosis and Treatment
Pelosof, L. C., & Gerber, D. E. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2010.0099 · Cited by 773
Szczepiorkowski, Z. M., Winters, J. L., Bandarenko, N., Kim, H. C., Linenberger, M. L., Marques, M. B., Sarode, R., Schwartz, J., Weinstein, R., & Shaz, B. H. (2010) · Journal of Clinical Apheresis · doi:10.1002/jca.20240 · Cited by 508
Metadata
- Authors
- Bain, P. G., Motomura, M., Newsom-Davis, J., Misbah, S. A., Chapel, H. M., Lee, M. L., Vincent, A., & Lang, B.
- Venue
- Neurology
- Published
- 1996-09
- Volume
- 47
- Issue
- 3
- Pages
- 678-683
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2063797334
- Cited by
- 261
- References
- 2
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of intravenous immunoglobulin on muscle weakness and calcium-channel autoantibodies in the Lambert-Eaton myasthenic syndrome. https://app.cochat.ai/papers/10.1212/wnl.47.3.678
- The paper
- Bain, P. G., Motomura, M., Newsom-Davis, J., Misbah, S. A., Chapel, H. M., Lee, M. L., Vincent, A., & Lang, B. (1996). Effects of intravenous immunoglobulin on muscle weakness and calcium-channel autoantibodies in the Lambert-Eaton myasthenic syndrome. Neurology. https://doi.org/10.1212/wnl.47.3.678
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.