The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Clinical utility of surface EMG [RETIRED]: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology
Open accessAbstract
This report reviews the clinical uses of surface electromyography (SEMG) as a diagnostic tool for neurologic disorders.SEMG is assessed with regard to the evaluation of patients with neuromuscular diseases, low back pain, and disorders of motor control.This broadens the scope of a previous assessment of SEMG in neurologic practice by the American Association of Electrodiagnostic Medicine 1 in which its utility was examined with regard to neuromuscular diseases only.Needle electromyographic evaluation (NEMG), in combination with nerve conduction studies, is the gold standard methodology for assessing the neurophysiologic characteristics of neuromuscular diseases.Moreover, fine-wire EMG (FWEMG) often has been used in the evaluation of gait disorders, kinesiologic studies, and research and is also considered a standard.Nevertheless, NEMG and FWEMG are both invasive and painful, and this limits their use when activity from several muscles needs to be monitored simultaneously.SEMG is a technique to measure muscle activity noninvasively using surface electrodes placed on the skin overlying the muscle.SEMG differs from NEMG and FWEMG with respect to technical requirements and electrical properties.Unlike NEMG, SEMG electrodes record from a wide area of muscle territory, have a relatively narrow frequency band (range, 20 to 500 Hz), have low-signal resolution, and are highly susceptible to movement artifact.SEMG electrodes typically are approximately 10 mm in diameter and usually are passive (i.e., they are simple conductive surfaces requiring low skin resistance).They can, however, be active, incorporating preamplifier electronics that lessen the need for low skin resistance and improve the signal-to-noise ratio.SEMG can record both voluntary and involuntary muscle activity in addition to externally stimulated muscle action potentials such as motor evoked potentials after central or peripheral nerve stimulation.2 SEMG has also been used in several non-neurologic settings such as obstetric monitoring and animal research, but these potential applications are beyond the scope of this review.More than 2500 original articles, reviews, and books were examined to determine the scope of SEMG utility, its benefits and risks, and the extent to which SEMG techniques vary, and to assess SEMG's strengths and weaknesses for specific clinical applications.Manual and computerized literature searches from the National Library of Medicine were used to obtain the articles.Key words used included SEMG, spontaneous activity, fasciculation, myopathy, muscle fiber conduction, motor unit estimation, fatigue, low-back pain, tremor, movement disorders, reaction time, and psychophysics.Representative articles are cited and listed at the end of this article.Other key words relating to neuromuscular diseases (other than when cross-referenced with SEMG) were not searched for specifically because this topic was the focus of the earlier AAEM assessment 1 and was not the main focus of the current paper. Neuromuscular diseases.No original article or review article has suggested that SEMG is better or even equivalent to NEMG in providing evidence of denervation at rest.This is because of the limited spatial resolution of SEMG that results in poor fidelity recordings of high-frequency signals such as polyphasic potentials, fibrillation potentials, and positive sharp waves.3 In addition, because of electrical cross-talk, SEMG cannot identify the origin of the electrical signal when two or more muscles, which lie in close proximity to each other, are active simultaneously.Furthermore, the electrical signals in SEMG recordings are often attenuated by intervening soft tissue, particularly when the active muscle is 10 mm or more below the skin surface.4 Insertional activity, another important measure in the evaluation of neuromuscular disease, 2,5 cannot be evaluated by SEMG for the self-evident reason that SEMG is noninvasive.Some studies have proposed that SEMG may be a useful adjunct in the evaluation of fasciculation, particularly in the assessment of patients with neuromuscular disease.In a review of 116 patients with a variety of neuromuscular conditions, including, among others, motor neuron disease (n = 43), neuropathy (n = 14), myelopathy or radiculopathy (n From the American Academy of Neurology, St. Paul, MN.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiologic and essential tremor
Elble, R. J. (1986) · Neurology · doi:10.1212/wnl.36.2.225 · Cited by 231
Cited by
Filtering the surface EMG signal: Movement artifact and baseline noise contamination
De Luca, C. J., Donald Gilmore, L., Kuznetsov, M., & Roy, S. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.027 · Cited by 1,277
Characterization of Surface EMG Signal Based on Fuzzy Entropy
Chen, W., Wang, Z., Xie, H., & Yu, W. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.897025 · Cited by 1,094
Clinical applications of high-density surface EMG: A systematic review
Drost, G., Stegeman, D. F., van Engelen, B. G. M., & Zwarts, M. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.09.005 · Cited by 311
Multichannel surface EMG: Basic aspects and clinical utility
Zwarts, M. J., & Stegeman, D. F. (2003) · Muscle & Nerve · doi:10.1002/mus.10358 · Cited by 302
Surface EMG in Clinical Assessment and Neurorehabilitation: Barriers Limiting Its Use
Campanini, I., Disselhorst-Klug, C., Rymer, W. Z., & Merletti, R. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00934 · Cited by 270
Metadata
- Authors
- Pullman, S. L., Goodin, D. S., Marquinez, A. I., Tabbal, S., & Rubin, M.
- Venue
- Neurology
- Published
- 2000-07-25
- Volume
- 55
- Issue
- 2
- Pages
- 171-177
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W1507137415
- Cited by
- 203
- References
- 1
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical utility of surface EMG [RETIRED]: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. https://app.cochat.ai/papers/10.1212/wnl.55.2.171
- The paper
- Pullman, S. L., Goodin, D. S., Marquinez, A. I., Tabbal, S., & Rubin, M. (2000). Clinical utility of surface EMG [RETIRED]: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Neurology. https://doi.org/10.1212/wnl.55.2.171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.