The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Characterization of Surface EMG Signal Based on Fuzzy Entropy
Abstract
Fuzzy entropy (FuzzyEn), a new measure of time series regularity, was proposed and applied to the characterization of surface electromyography (EMG) signals. Similar to the two existing related measures ApEn and SampEn, FuzzyEn is the negative natural logarithm of the conditional probability that two vectors similar for m points remain similar for the next m + 1 points. Importing the concept of fuzzy sets, vectors' similarity is fuzzily defined in FuzzyEn on the basis of exponential function and their shapes. Besides possessing the good properties of SampEn superior to ApEn, FuzzyEn also succeeds in giving the entropy definition in the case of small parameters. Its performance on characterizing surface EMG signals, as well as independent, identically distributed (i.i.d.) random numbers and periodical sinusoidal signals, shows that FuzzyEn can more efficiently measure the regularity of time series. The method introduced here can also be applied to other noisy physiological signals with relatively short datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
The dynamics of resting and postural tremor in Parkinson's disease
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00467-3 · Cited by 210
Cited by
EEG entropy measures in anesthesia
Liang, Z., Wang, Y., Sun, X., Li, D., Voss, L. J., Sleigh, J. W., Hagihira, S., & Li, X. (2015) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2015.00016 · Cited by 306
A Review of EEG Signal Features and Their Application in Driver Drowsiness Detection Systems
Stancin, I., Cifrek, M., & Jovic, A. (2021) · Sensors · doi:10.3390/s21113786 · Cited by 269
Review and classification of variability analysis techniques with clinical applications
Bravi, A., Longtin, A., & Seely, A. J. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-90 · Cited by 265
Artificial Intelligence Techniques for Automated Diagnosis of Neurological Disorders
Raghavendra, U., Acharya, U. R., & Adeli, H. (2019) · European Neurology · doi:10.1159/000504292 · Cited by 174
Dynamic entropy-based pattern learning to identify emotions from EEG signals across individuals
Lu, Y., Wang, M., Wu, W., Han, Y., Zhang, Q., & Chen, S. (2020) · Measurement · doi:10.1016/j.measurement.2019.107003 · Cited by 73
Metadata
- Authors
- Chen, W., Wang, Z., Xie, H., & Yu, W.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-06
- Volume
- 15
- Issue
- 2
- Pages
- 266-272
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2164104048
- Cited by
- 1,094
- References
- 2
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Surface EMG Signal Based on Fuzzy Entropy. https://app.cochat.ai/papers/10.1109/tnsre.2007.897025
- The paper
- Chen, W., Wang, Z., Xie, H., & Yu, W. (2007). Characterization of Surface EMG Signal Based on Fuzzy Entropy. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2007.897025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.