Differences in spatial acuity between digits
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The spatial acuity of the index, middle, and ring distal finger pads of eight right-handed men, aged 22 to 57 years, was measured by using gratings and raised letters. Acuity declined significantly from the index to the middle finger and from the middle to the ring finger. There were no significant differences between homologous fingers of the two hands. Letter recognition and grating orientation threshold measures were highly correlated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tactile spatial resolution in blind Braille readers
Boven, R. W. V., Hamilton, R. H., Kauffman, T., Keenan, J. P., & Pascual–Leone, A. (2000) · Neurology · doi:10.1212/wnl.54.12.2230 · Cited by 380
Cited by
Vibrotactile Display: Perception, Technology, and Applications
Choi, S., & Kuchenbecker, K. J. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2221071 · Cited by 496
Tactile Acuity is Enhanced in Blindness
Goldreich, D., & Kanics, I. M. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-08-03439.2003 · Cited by 427
An implicit body representation underlying human position sense
Longo, M. R., & Haggard, P. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003483107 · Cited by 381
Warm or Cool, Large or Small? The Challenge of Thermal Displays
Jones, L. A., & Ho, H.-N. (2008) · IEEE Transactions on Haptics · doi:10.1109/toh.2008.2 · Cited by 236
“The tactile spatial resolution of the skin has been measured using a number of different methods, including gap detection, grating orientation, and point localization, all of which have demonstrated the remarkable tactile acuity of the skin [55], [56].”
MethodHuman finger somatotopy in areas 3b, 1, and 2: A 7T fMRI study using a natural stimulus
Martuzzi, R., van der Zwaag, W., Farthouat, J., Gruetter, R., & Blanke, O. (2014) · Human Brain Mapping · doi:10.1002/hbm.22172 · Cited by 213
Tactile Spatial Acuity Enhancement in Blindness: Evidence for Experience-Dependent Mechanisms
Wong, M., Gnanakumaran, V., & Goldreich, D. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.6461-10.2011 · Cited by 183
“We found further that acuity worsens from index to middle to ring fingertips, consistent with previous reports show- ing significant effects or trends in this direction (Sathian and Zangaladze, 1996; Vega-Bermudez and Johnson, 2001; Grant et al., 2006; Duncan and Boynton, 2007).”
ResultFinger-Shaped GelForce: Sensor for Measuring Surface Traction Fields for Robotic Hand
Sato, K., Kamiyama, K., Kawakami, N., & Tachi, S. (2010) · IEEE Transactions on Haptics · doi:10.1109/toh.2009.47 · Cited by 172
“7 mm [4], and perceive vibration up to 700 Hz [5].”
BackgroundImplicit body representations and the conscious body image
Longo, M. R., & Haggard, P. (2012) · Acta Psychologica · doi:10.1016/j.actpsy.2012.07.015 · Cited by 168
“As previously noted (Longo & Haggard, 2010), this gradient mirrors gradients across the fingers both for tactile acuity (Vega-Bermudez & Johnson, 2001) and cortical magnification (Duncan & Boynton, 2007).”
Sensory capacity of reinnervated skin after redirection of amputated upper limb nerves to the chest
Marasco, P. D., Schultz, A. E., & Kuiken, T. A. (2009) · Brain · doi:10.1093/brain/awp082 · Cited by 113
Design of electrotactile stimulation to represent distribution of force vectors
Sato, K., & Tachi, S. (2010) · 2010 IEEE Haptics Symposium · doi:10.1109/haptic.2010.5444666 · Cited by 44
A Performance Comparison of On-Hand versus On-Phone Nonvisual Input by Blind and Sighted Users
Oh, U., & Findlater, L. (2015) · ACM Transactions on Accessible Computing · doi:10.1145/2820616 · Cited by 23
Metadata
- Authors
- Vega–Bermudez, F., & Johnson, K. O.
- Venue
- Neurology
- Published
- 2001-05-22
- Volume
- 56
- Issue
- 10
- Pages
- 1389-1391
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2020227161
- Cited by
- 95
- References
- 1
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.