The DOI matches its Crossref record.
Precision and Accuracy of Intraoperative Temperature Monitoring
Abstract
Using tympanic membrane (TM) temperature as a standard for core temperature, we quantitated the accuracy and precision of seven other temperature monitoring sites during anesthesia, namely, the nasopharynx, esophagus, rectum, bladder, axilla, forehead, and great toe. Accuracy was quantitated as the difference between TM temperature and the temperature at each of the other sites; precision was quantitated as the correlation between TM temperature and the temperature at each of the other sites. Results indicate that the accuracy of measurements made using the great toe, forehead, and axilla is less than the accuracy of measurements made using the nasopharynx, esophagus, bladder, and rectum. Precision of measurements made using the nasopharynx, esophagus, and bladder is greater than the precision at the axilla, forehead, and rectum, and much higher than the precision at the great toe. Measurements of body temperature using the nasopharynx, esophagus, and bladder are recommended for intraoperative use as providing the best combination of accuracy and precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mild Perioperative Hypothermia
Sessler, D. I. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362407 · Cited by 659
Lefrant, J.-Y., Muller, L., de La Coussaye, J. E., Benbabaali, M., Lebris, C., Zeitoun, N., Mari, C., Saïssi, G., Ripart, J., & Eledjam, J.-J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1619-5 · Cited by 303
Caughey, A. B., Wood, S. L., Macones, G. A., Wrench, I. J., Huang, J., Norman, M., Pettersson, K., Fawcett, W. J., Shalabi, M. M., Metcalfe, A., et al. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.08.006 · Cited by 273
Evaluation of the Temple Touch Pro, a Novel Noninvasive Core-Temperature Monitoring System
Evron, S., Weissman, A., Toivis, V., Shahaf, D. B., You, J., Sessler, D. I., & Ezri, T. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001695 · Cited by 38
Metadata
- Authors
- Cork, R. C., Vaughan, R. W., & Humphrey, L. S.
- Venue
- Anesthesia & Analgesia
- Published
- 1983-02
- Volume
- 62
- Issue
- 2
- Pages
- 211???214
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W4242400252
- Cited by
- 168
- References
- 0
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precision and Accuracy of Intraoperative Temperature Monitoring. https://app.cochat.ai/papers/10.1213/00000539-198302000-00016
- The paper
- Cork, R. C., Vaughan, R. W., & Humphrey, L. S. (1983). Precision and Accuracy of Intraoperative Temperature Monitoring. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-198302000-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.