Evaluation of the Temple Touch Pro, a Novel Noninvasive Core-Temperature Monitoring System

Evron, Shmuel, Weissman, Avi, Toivis, Vadim, Shahaf, Dana Baron, You, Jing, Sessler, Daniel I., Ezri, Tiberiu·2017·Anesthesia & Analgesia

Abstract

BACKGROUND: The Temple Touch Pro (TTP) is a novel system that estimates core temperature from skin over the temporal artery. We tested the hypothesis that this noninvasive system estimates core temperature to an accuracy within 0.5°C. METHODS: Core temperature was continuously monitored in 50 adult and pediatric surgical patients by positioning the sensor patch of a TTP over one temporal artery. The sensor consists of a thermistor array near the skin surface, another set of thermistors above an insulator, and a second insulator between the upper unit and the environment. The sensor measures skin temperature and heat flux, from which the monitor unit estimates core temperature from a proprietary algorithm. Reference core temperature was measured from the esophagus or nasopharynx. We conducted agreement analysis between the TTP and the reference core temperature measurements using the 95% Bland-Altman limits of agreement for repeated measurement data. The proportion of all differences that were within 0.5°C and repeat measures concordance correlation coefficient (CCC) were estimated as well. RESULTS: TTP and the reference core temperature measurements agreed well in both adults and pediatric patients. Bland-Altman plots showed no evidence of systematic bias or variability over the temperature from 35.2°C to 37.8°C. The estimated 95% lower and upper limits of agreement were −0.57°C (95% confidence interval [CI], −0.76 to −0.41) and 0.57°C (95% CI, 0.44 to 0.71), indicating good agreement between the 2 methods. Ninety-four percentage (95% CI, 87% to 99%) of the TTP temperatures were within 0.5°C of the reference temperature. Good agreement was also supported by an estimated repeated measures CCC of 0.82 (95% CI, 0.66 to 0.91). The TTP core temperature measurements also agreed well with nasopharyngeal reference temperatures. CONCLUSIONS: The noninvasive TTP system is sufficiently accurate and reliable for routine intraoperative core temperature monitoring.

Integrity signals

Registry

Crossref · 10.1213/ane.0000000000001695

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Double Sensor provides a reliable and valid estimate of core body temperature.

    “This approach has been tested in various space analogs and clinical settings and has been found to provide a reliable and valid estimate of CBT20–23.”
  • The sensor probe applied to the forehead is a highly accurate surrogate compared to nasopharyngeal, esophageal and artery temperatures.

    “Importantly, the sensor probe can be applied to the forehead, and has been shown to be highly accurate surrogate compared to nasopharyngeal20, esophageal23–27 and artery temperatures24.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Evron, S., Weissman, A., Toivis, V., Shahaf, D. B., You, J., Sessler, D. I., & Ezri, T.
Affiliations
  • Tel Aviv University (IL)
  • Technion – Israel Institute of Technology (IL)
  • Cleveland Clinic (US)
  • Department of Outcomes Research, Anesthesiology Institute, Cleveland, Ohio.
Corresponding author
  • Evron, Shmuel
  • Toivis, Vadim
  • Ezri, Tiberiu
Venue
Anesthesia & Analgesia
Published
2017-07
Volume
125
Issue
1
Pages
103-109
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2626403611
Cited by
38
References
26
Citations by year
2026: 1 · 2025: 3 · 2024: 6 · 2023: 3 · 2022: 7 · 2021: 5 · 2020: 5 · 2019: 5 · 2018: 2 · 2017: 1
FWCI
3.33
Type
journal article
Language
en
Open access
closed
Locations
  • Anesthesia & Analgesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
core body temperature monitoring, temporal artery, skin temperature, heat flux, intraoperative hypothermia, surgical patients, pediatric patients, esophageal temperature, nasopharyngeal temperature, measurement agreement
MeSH terms
Adolescent, Adult, Aged, Body Temperature Regulation, Child, Child, Preschool, Equipment Design, Female, Humans, Infant, Israel, Male, Middle Aged, Predictive Value of Tests, Skin Temperature, Temporal Arteries, Thermography, Transducers, Reproducibility of Results, Monitoring, Intraoperative, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review