Pulmonary Aspiration???Effects of Volume and pH in the Rat
The DOI matches its Crossref record.
Abstract
To evaluate the effect of volume of aspirates with different pHs on mortality associated with pulmonary aspiration, hydrochloric acid solutions were injected into the tracheas of 336 Sprague-Dawley rats. The rats were divided randomly into 33 groups, were observed for 96 hr after aspiration, and were not resuscitated. Deaths were divided into two groups: early, less than 30 min after aspiration, and late, greater than 4 hr after aspiration. Late deaths, accounting for 22% of all fatalities, occurred exclusively in animals aspirating solutions with a pH less than 2.5. These late deaths indicated progressive lung damage as opposed to acute cardiorespiratory failure, which early deaths suggested. Low volume pulmonary aspirates (0.3 ml/kg) with extremely low pH (1.0) resulted in a high mortality rate (90%). Conversely, higher volume pulmonary aspirates (1.0-2.0 ml/kg) with a higher pH (greater than or equal to 1.8) resulted in a low mortality rate (14%). These data demonstrate an important interaction between pH and volume of aspirates: even low volumes have a high mortality rate if pH is very low, whereas if gastric fluid is effectively buffered, then much higher volumes than previously thought can be tolerated. This suggests that the routine use of nonparticulate antacids may be indicated in patients at risk from aspiration of stomach contents and should not be withheld because of concern of increasing gastric volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aspiration Pneumonitis and Aspiration Pneumonia
Marik, P. E. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103013440908 · Cited by 1,627
Preoperative fasting for adults to prevent perioperative complications
Brady, M. C., Kinn, S., Stuart, P., & Ness, V. (2003) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004423 · Cited by 694
Gastroesophageal Reflux and Aspiration of Gastric Contents in Anesthetic Practice
Ng, A., & Smith, G. (2001) · Anesthesia & Analgesia · doi:10.1213/00000539-200108000-00050 · Cited by 241
Preoperative fasting for preventing perioperative complications in children
Brady, M. C., Kinn, S., Ness, V., O'Rourke, K., Randhawa, N., & Stuart, P. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005285.pub2 · Cited by 210
Bedside ultrasound assessment of gastric content: an observational study
Cubillos, J., Tse, C., Chan, V. W. S., & Perlas, A. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-011-9661-9 · Cited by 179
Metadata
- Authors
- James, C. F., Modell, J. H., Gibbs, C. P., Kuck, E. J., & Ruiz, B. C.
- Venue
- Anesthesia & Analgesia
- Published
- 1984-07
- Volume
- 63
- Issue
- 7
- Pages
- 665???668
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2060132792
- Cited by
- 216
- References
- 0
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary Aspiration???Effects of Volume and pH in the Rat. https://app.cochat.ai/papers/10.1213/00000539-198407000-00007
- The paper
- James, C. F., Modell, J. H., Gibbs, C. P., Kuck, E. J., & Ruiz, B. C. (1984). Pulmonary Aspiration???Effects of Volume and pH in the Rat. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-198407000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.